Parameters Affecting the Shear-Friction Strength of a Construction Joint in a Squat Wall Subjected to Cyclic Loading

In the present study, the seismic shear-friction behavior of squat reinforced concrete walls with a construction joint was investigated. To investigate the effect of flexural moment on the shear-friction behavior, 10 wall specimens—rather than conventional push-off (direct shear) specimens—were tested under cyclic lateral loading. The test parameters were the surface roughness, surface roughening method, reinforcement ratio, reinforcement diameter, section geometry, wall aspect ratio, and reinforcement arrangement. The test results showed that roughened interface increased the shear-friction strength, but the difference between roughening methods was marginal. When large diameter rebars were used, the strength degradation due to the cyclic loading effect was less significant. Further, even when the overall amount of reinforcement was uniform, the shear-friction strength increased as the flexural strength–demand ratio increased due to the low aspect ratio and the use of flange. The test results, along with previous studies on shear-friction walls, were compared with the predictions of current design codes, and the effect of design parameters affecting the shear-friction strength were discussed. A nonlinear macro shear-sliding model for shear walls overestimated postyield strength and initial stiffness and underestimated residual strength.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2025-10-29
DOI
https://doi.org/10.1061/jsendh.steng-14910
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameters Affecting the Shear-Friction Strength of a Construction Joint in a Squat Wall Subjected to Cyclic Loading

Hong‐Gun Park, Jae-Han Oh
Journal of Structural Engineering
Seismic Performance and Analysis
article

Parameters Affecting the Shear-Friction Strength of a Construction Joint in a Squat Wall Subjected to Cyclic Loading

Hong‐Gun Park, Jae-Han Oh
article en

Abstract

In the present study, the seismic shear-friction behavior of squat reinforced concrete walls with a construction joint was investigated. To investigate the effect of flexural moment on the shear-friction behavior, 10 wall specimens—rather than conventional push-off (direct shear) specimens—were tested under cyclic lateral loading. The test parameters were the surface roughness, surface roughening method, reinforcement ratio, reinforcement diameter, section geometry, wall aspect ratio, and reinforcement arrangement. The test results showed that roughened interface increased the shear-friction strength, but the difference between roughening methods was marginal. When large diameter rebars were used, the strength degradation due to the cyclic loading effect was less significant. Further, even when the overall amount of reinforcement was uniform, the shear-friction strength increased as the flexural strength–demand ratio increased due to the low aspect ratio and the use of flange. The test results, along with previous studies on shear-friction walls, were compared with the predictions of current design codes, and the effect of design parameters affecting the shear-friction strength were discussed. A nonlinear macro shear-sliding model for shear walls overestimated postyield strength and initial stiffness and underestimated residual strength.

Journal of Structural EngineeringVol. 152(1)
Seoul National University (KR)
Openalex Percentile: Top 67%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parameters Affecting the Shear-Friction Strength of a Construction Joint in a Squat Wall Subjected to Cyclic Loading — Hong‐Gun Park, Jae-Han Oh · Journal of Structural Engineering (2025) | TGRS Research Map | TGRS