Variation in and deviation from protective ventilation during lung surgery
Adherence to lung-protective ventilation recommendations was low. Higher peak inspiratory pressure is associated with PPCs, supporting barotrauma during OLV as a culprit. This is a target for quality assessment and knowledge translation efforts.