Synchronizing droplet microfluidics and ion mobility spectrometry via the electrospray current recorded with a tailored low-noise, high-gain current amplifier

In the process of coupling ion mobility spectrometry (IMS) and droplet microfluidics, the sample to be analyzed is ionized by electrospray ionization (ESI), thereby transferring the liquid samples into the gas phase with concurrent ionization. In contradistinction to conventional ESI, in droplet microfluidics the sample to be analyzed is present in individual droplets, which are separated from each other by an oil phase resulting in the process of ESI becoming discontinuous due to alternating sample droplets and oil phase. Typically, averaging is necessary in IMS to suppress noise and thus improve detection limits. However, in combination with droplet microfluidics, continuous averaging leads to reduced signal-to-noise ratio, because the spectra of the oil phase not containing any information are included into averaging. To avoid this effect, it is imperative to synchronize the ESI-IMS with the droplet microfluidics using a suited trigger signal. Therefore, we present a fast, low-noise, high-gain current amplifier that can operate at high electrical potential and allows for monitoring the ESI current in both polarities. The design of this amplifier is predicated on the current change of the ESI current during the volume transition between oil and droplet inside the emitter. This transition has been mathematically modelled and incorporated as a volume-dependent term within an existing equation for the ESI current. Finally, we present experimental data to support the idea of increasing signal-to-noise ratio by triggering the ESI-IMS via the electrospray current. Furthermore, triggering the IMS facilitates droplet-wise storage of data.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-10-29
DOI
https://doi.org/10.1016/j.talanta.2025.129040
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synchronizing droplet microfluidics and ion mobility spectrometry via the electrospray current recorded with a tailored low-noise, high-gain current amplifier

Stefan Zimmermann, Christian Thoben, Alexander Nitschke, Detlev Belder et al.
Talanta
Mass Spectrometry Techniques and Applications
article

Synchronizing droplet microfluidics and ion mobility spectrometry via the electrospray current recorded with a tailored low-noise, high-gain current amplifier

Stefan Zimmermann, Christian Thoben, Alexander Nitschke, Detlev Belder, Moritz Hitzemann, Klaus Welters, Tim Ostermeier
article en

Abstract

In the process of coupling ion mobility spectrometry (IMS) and droplet microfluidics, the sample to be analyzed is ionized by electrospray ionization (ESI), thereby transferring the liquid samples into the gas phase with concurrent ionization. In contradistinction to conventional ESI, in droplet microfluidics the sample to be analyzed is present in individual droplets, which are separated from each other by an oil phase resulting in the process of ESI becoming discontinuous due to alternating sample droplets and oil phase. Typically, averaging is necessary in IMS to suppress noise and thus improve detection limits. However, in combination with droplet microfluidics, continuous averaging leads to reduced signal-to-noise ratio, because the spectra of the oil phase not containing any information are included into averaging. To avoid this effect, it is imperative to synchronize the ESI-IMS with the droplet microfluidics using a suited trigger signal. Therefore, we present a fast, low-noise, high-gain current amplifier that can operate at high electrical potential and allows for monitoring the ESI current in both polarities. The design of this amplifier is predicated on the current change of the ESI current during the volume transition between oil and droplet inside the emitter. This transition has been mathematically modelled and incorporated as a volume-dependent term within an existing equation for the ESI current. Finally, we present experimental data to support the idea of increasing signal-to-noise ratio by triggering the ESI-IMS via the electrospray current. Furthermore, triggering the IMS facilitates droplet-wise storage of data.

TalantaVol. 298(Pt B)
Leibniz University Hannover (DE), Leipzig University (DE)
Openalex Percentile: Top 71%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.