Computational corrections for anisotropic absorption in tensor tomography

In X-ray scattering tensor tomography at large scattering angles, the absorption of scattered X-rays by the sample itself is anisotropic due to the macroscopic geometry of the sample. This effect is mostly ignored or only treated approximately in established reconstruction algorithms. In this paper we perform a simulation study to estimate the severity of the problem and suggest and test a computational approach to correct for this effect. We also investigate experimental scattering data from hydroxyapatite scattering from a piece of beaver tooth where the same trends from the simulations can be observed. We conclude that the conventional approach to transmission correction yields good results at scattering angles and levels of absorption normally used.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-10-16
DOI
https://doi.org/10.1107/s1600577525008641
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational corrections for anisotropic absorption in tensor tomography

Marianne Liebi, Mads Carlsen
Journal of Synchrotron Radiation
Radiation Shielding Materials Analysis
article

Computational corrections for anisotropic absorption in tensor tomography

Marianne Liebi, Mads Carlsen
article en

Abstract

In X-ray scattering tensor tomography at large scattering angles, the absorption of scattered X-rays by the sample itself is anisotropic due to the macroscopic geometry of the sample. This effect is mostly ignored or only treated approximately in established reconstruction algorithms. In this paper we perform a simulation study to estimate the severity of the problem and suggest and test a computational approach to correct for this effect. We also investigate experimental scattering data from hydroxyapatite scattering from a piece of beaver tooth where the same trends from the simulations can be observed. We conclude that the conventional approach to transmission correction yields good results at scattering angles and levels of absorption normally used.

Journal of Synchrotron RadiationVol. 32(6)
Paul Scherrer Institute (CH), École Polytechnique Fédérale de Lausanne (CH)
European Commission, Paul Scherrer Institut
Openalex Percentile: Top 75%
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Computational corrections for anisotropic absorption in tensor tomography — Marianne Liebi, Mads Carlsen · Journal of Synchrotron Radiation (2025) | TGRS Research Map | TGRS