Trichel Pulse Mode and the Stage Preceding It during Corona Discharge

Study of negative corona discharge in atmospheric air has been performed. The discharge was initiated between point cathode and plane anode placed at a distance of 10–20 mm, radius of curvature of the cathode needle was about 20 µm. It is shown that at the discharge stage preceding the Trichel pulse mode, the discharge current is not detected within the measurement error of ±0.2 nA. It was shown that when voltage across the gap is close to the threshold of corona discharge ignition, after the current of the first Trichel pulse has dropped to 20–25 nA during ∼250 µs the current continues to decrease to zero within ∼700 µs. It was found for the first time that in a certain range of applied voltage, the Trichel pulse mode after its initiation becomes unstable and periodically changes to a pulseless discharge mode with a current of $$ \lesssim {\kern 1pt} 1$$ µA.

Authors

Institutions

Publication Details

Journal
Bulletin of the Russian Academy of Sciences Physics
Published
2025-10-01
DOI
https://doi.org/10.1134/s1062873825712851
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trichel Pulse Mode and the Stage Preceding It during Corona Discharge

В. Ф. Тарасенко, Е. Х. Бакшт, A. N. Panchenko
Bulletin of the Russian Academy of Sciences Physics
Plasma Applications and Diagnostics
article

Trichel Pulse Mode and the Stage Preceding It during Corona Discharge

В. Ф. Тарасенко, Е. Х. Бакшт, A. N. Panchenko
article en

Abstract

Study of negative corona discharge in atmospheric air has been performed. The discharge was initiated between point cathode and plane anode placed at a distance of 10–20 mm, radius of curvature of the cathode needle was about 20 µm. It is shown that at the discharge stage preceding the Trichel pulse mode, the discharge current is not detected within the measurement error of ±0.2 nA. It was shown that when voltage across the gap is close to the threshold of corona discharge ignition, after the current of the first Trichel pulse has dropped to 20–25 nA during ∼250 µs the current continues to decrease to zero within ∼700 µs. It was found for the first time that in a certain range of applied voltage, the Trichel pulse mode after its initiation becomes unstable and periodically changes to a pulseless discharge mode with a current of $$ \lesssim {\kern 1pt} 1$$ µA.

Bulletin of the Russian Academy of Sciences PhysicsVol. 89(10)
Institute of High Current Electronics (RU)
Openalex Percentile: Top 54%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Trichel Pulse Mode and the Stage Preceding It during Corona Discharge — В. Ф. Тарасенко, Е. Х. Бакшт, et al. · Bulletin of the Russian Academy of Sciences Physics (2025) | TGRS Research Map | TGRS