Assessing the accuracy of the coupled-spherical-bubble approach for bubble pairs in an acoustic field

This study evaluates the accuracy of coupled-spherical-bubble models in acoustic fields by comparing them to direct numerical simulations (DNS). The coupled-spherical-bubble approach refers to the method of modeling multi-bubble systems, where the spherical bubble dynamics are governed by a simplified equation and these equations are coupled through the pressure emissions of the bubbles. Tested spherical models are the Keller-Miksis and Gilmore equation, and pressure emission models include the incompressible, quasi-acoustic and Kirkwood-Bethe hypothesis. Emphasis is placed on peak bubble pressure during collapse and the accuracy of pressure emission models. First, a single bubble in a spherical standing wave is analyzed. Among the simplified approaches, the Gilmore model provides closer agreement with DNS at Mach numbers approaching unity in water. In high-viscosity glycerol spherical models break down independently of the Mach number. Pressure wave emissions are accurately tracked by all tested models that assume a finite propagation velocity; however, shock wave emissions at high compression ratios can only be tracked by the Kirkwood-Bethe model. In the second part, a bubble pair is subjected to an ultrasonic pulse, and spherical volume oscillations and pressure emissions of bubbles are compared using various coupled-spherical-bubble approaches. DNS results show that jetting during collapse reduces gas compression, leading spherical models to overpredict internal pressure. While spherical models are effective for isolated bubbles in ideal conditions, DNS is essential for accurately capturing inter-bubble interactions. Nevertheless, spherical models provide good accuracy in the case of a bubble collapse without jetting, even when perfect sphericity is not preserved.

Authors

Institutions

Publication Details

Journal
Ultrasonics Sonochemistry
Published
2025-10-28
DOI
https://doi.org/10.1016/j.ultsonch.2025.107651
Citations
2
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the accuracy of the coupled-spherical-bubble approach for bubble pairs in an acoustic field

Dániel Nagy, Ferenc Hegedűs
2 citations
Ultrasonics Sonochemistry
Ultrasound and Cavitation Phenomena
1.04
article

Assessing the accuracy of the coupled-spherical-bubble approach for bubble pairs in an acoustic field

Dániel Nagy, Ferenc Hegedűs
article en
2 citations

Abstract

This study evaluates the accuracy of coupled-spherical-bubble models in acoustic fields by comparing them to direct numerical simulations (DNS). The coupled-spherical-bubble approach refers to the method of modeling multi-bubble systems, where the spherical bubble dynamics are governed by a simplified equation and these equations are coupled through the pressure emissions of the bubbles. Tested spherical models are the Keller-Miksis and Gilmore equation, and pressure emission models include the incompressible, quasi-acoustic and Kirkwood-Bethe hypothesis. Emphasis is placed on peak bubble pressure during collapse and the accuracy of pressure emission models. First, a single bubble in a spherical standing wave is analyzed. Among the simplified approaches, the Gilmore model provides closer agreement with DNS at Mach numbers approaching unity in water. In high-viscosity glycerol spherical models break down independently of the Mach number. Pressure wave emissions are accurately tracked by all tested models that assume a finite propagation velocity; however, shock wave emissions at high compression ratios can only be tracked by the Kirkwood-Bethe model. In the second part, a bubble pair is subjected to an ultrasonic pulse, and spherical volume oscillations and pressure emissions of bubbles are compared using various coupled-spherical-bubble approaches. DNS results show that jetting during collapse reduces gas compression, leading spherical models to overpredict internal pressure. While spherical models are effective for isolated bubbles in ideal conditions, DNS is essential for accurately capturing inter-bubble interactions. Nevertheless, spherical models provide good accuracy in the case of a bubble collapse without jetting, even when perfect sphericity is not preserved.

Ultrasonics SonochemistryVol. 123
Budapest University of Technology and Economics (HU)
Openalex Percentile: Top 21%
Ultrasound and Cavitation Phenomena
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing the accuracy of the coupled-spherical-bubble approach for bubble pairs in an acoustic field — Dániel Nagy, Ferenc Hegedűs · Ultrasonics Sonochemistry (2025) | TGRS Research Map | TGRS