Accurate Quantification of <sup>45</sup> N <sub>2</sub> O with a Membrane Inlet Mass Spectrometer by Optimizing the Temperature of a Cold Trap

Membrane Inlet Mass Spectrometry (MIMS) is extensively applied in the study of nitrogen cycling processes. However, robust methods for the quantitative detection of N<sub>2</sub>O by this technique are still scarce. In this study, acidified azide was employed to reduce <sup>15</sup>NO<sub>2</sub> <sup>-</sup> to generate <sup>45</sup>N<sub>2</sub>O, which was used to make a standard curve for qualifying <sup>45</sup>N<sub>2</sub>O with MIMS. Key parameters affecting the azide reduction, including reagent concentration, reaction time, reaction mode, and salinity, were systematically evaluated and optimized. Then, the generated <sup>45</sup>N<sub>2</sub>O dissolved in water was introduced into the MIMS via a cold trap maintained at -88 ± 2 °C. This specific temperature capitalizes on the difference in the freezing points of N<sub>2</sub>O (-91 °C) and CO<sub>2</sub> (-78 °C), thereby effectively minimizing CO<sub>2</sub> interference during N<sub>2</sub>O measurement. Under optimized conditions, the linear fitting between <sup>45</sup>N<sub>2</sub>O ion current intensity and expected <sup>45</sup>N<sub>2</sub>O concentration showed an excellent linearity in the range of 0.1-100 μmol/L (<i>R</i> <sup>2</sup> = 0.998), with a detection limit of 0.1 μmol/L. This method achieves accurate (relative error: 4.688%) and precise (relative standard deviation: 1.560%) detection of <sup>45</sup>N<sub>2</sub>O and holds potential for future application in tracing microbial N<sub>2</sub>O source-sink processes across diverse habitats.

Authors

Institutions

Publication Details

Journal
JACS Au
Published
2025-10-28
DOI
https://doi.org/10.1021/jacsau.5c01146
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate Quantification of 45 N 2 O with a Membrane Inlet Mass Spectrometer by Optimizing the Temperature of a Cold Trap

Baoshan Zhang, Zhiming Qu, Yiguo Hong, Hui Zhao et al.
JACS Au
Mass Spectrometry Techniques and Applications
article

Accurate Quantification of 45 N 2 O with a Membrane Inlet Mass Spectrometer by Optimizing the Temperature of a Cold Trap

Baoshan Zhang, Zhiming Qu, Yiguo Hong, Hui Zhao, Jiapeng Wu, C. Kuang, Xiaomei Shen
article en

Abstract

Membrane Inlet Mass Spectrometry (MIMS) is extensively applied in the study of nitrogen cycling processes. However, robust methods for the quantitative detection of N<sub>2</sub>O by this technique are still scarce. In this study, acidified azide was employed to reduce <sup>15</sup>NO<sub>2</sub> <sup>-</sup> to generate <sup>45</sup>N<sub>2</sub>O, which was used to make a standard curve for qualifying <sup>45</sup>N<sub>2</sub>O with MIMS. Key parameters affecting the azide reduction, including reagent concentration, reaction time, reaction mode, and salinity, were systematically evaluated and optimized. Then, the generated <sup>45</sup>N<sub>2</sub>O dissolved in water was introduced into the MIMS via a cold trap maintained at -88 ± 2 °C. This specific temperature capitalizes on the difference in the freezing points of N<sub>2</sub>O (-91 °C) and CO<sub>2</sub> (-78 °C), thereby effectively minimizing CO<sub>2</sub> interference during N<sub>2</sub>O measurement. Under optimized conditions, the linear fitting between <sup>45</sup>N<sub>2</sub>O ion current intensity and expected <sup>45</sup>N<sub>2</sub>O concentration showed an excellent linearity in the range of 0.1-100 μmol/L (<i>R</i> <sup>2</sup> = 0.998), with a detection limit of 0.1 μmol/L. This method achieves accurate (relative error: 4.688%) and precise (relative standard deviation: 1.560%) detection of <sup>45</sup>N<sub>2</sub>O and holds potential for future application in tracing microbial N<sub>2</sub>O source-sink processes across diverse habitats.

JACS AuVol. 5(11)
Guangzhou University (CN), Guangdong Ocean University (CN)
Openalex Percentile: Top 71%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate Quantification of <sup>45</sup> N <sub>2</sub> O with a Membrane Inlet Mass Spectrometer by Optimizing the Temperature of a Cold Trap — Baoshan Zhang, Zhiming Qu, et al. · JACS Au (2025) | TGRS Research Map | TGRS