Enhanced Solubility and Electron Transfer of Osmium-Based Mediators via Quaternized Poly(4-Vinylpyridine) for Electrochemical Glucose Detection

Hydrophilic polymer-osmium complexes enhance electron transfer between enzymes and electrodes in biosensors. In this study, hydrophobic poly(4-vinylpyridine) (PVP) was quaternized with 2-bromoethanol to synthesize water-soluble PVP(Q)-C<sub>2</sub>H<sub>4</sub>OH polymers (MW 60,000 and 160,000). The resulting PVP(Q)-C<sub>2</sub>H<sub>4</sub>OH-Os(dmo-bpy)<sub>2</sub>Cl complexes were verified by UV-Vis, FT-IR, 1H NMR, SEM-EDS, and zeta potential analyses, confirming successful quaternization and osmium coordination with good dispersion stability. Electrochemical tests (cyclic voltammetry, multi-potential step, amperometry) demonstrated that electrodes with quaternized mediators showed greatly enhanced catalytic currents for glucose (0-20 mM), with sensitivities of 6.9791 (MW 60,000) and 6.6279 μA·mM<sup>-1</sup>·cm<sup>-2</sup> (MW 160,000), respectively, which were 6.6-10.3 times higher than those of non-quaternized polymers. Selectivity tests showed negligible interference from common species such as ascorbic acid, dopamine, uric acid, and serotonin. Continuous glucose monitoring (CGM) electrodes were fabricated by immobilizing the mediator and glucose dehydrogenase on silanized Au electrodes. SEM, scan rate, and impedance analyses confirmed stable binding. The modified electrodes showed strong linearity (R<sup>2</sup> = 0.992) and high sensitivity (2.56 μA·mM<sup>-1</sup>·cm<sup>-2</sup>), and good stability, maintaining ~82% activity for seven days. Human plasma testing validated accurate glucose detection (6.05 mM), consistent with physiological levels. Overall, quaternized PVP(Q) mediators significantly improved solubility and electron transfer, enabling the development of a stable, selective glucose sensor suitable for CGM applications.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-10-28
DOI
https://doi.org/10.3390/polym17212874
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Solubility and Electron Transfer of Osmium-Based Mediators via Quaternized Poly(4-Vinylpyridine) for Electrochemical Glucose Detection

Won‐Yong Jeon, Taewon Seo, Young-Bong Choi, Youl Hee Cho
Polymers
Electrochemical sensors and biosensors
article

Enhanced Solubility and Electron Transfer of Osmium-Based Mediators via Quaternized Poly(4-Vinylpyridine) for Electrochemical Glucose Detection

Won‐Yong Jeon, Taewon Seo, Young-Bong Choi, Youl Hee Cho
article en

Abstract

Hydrophilic polymer-osmium complexes enhance electron transfer between enzymes and electrodes in biosensors. In this study, hydrophobic poly(4-vinylpyridine) (PVP) was quaternized with 2-bromoethanol to synthesize water-soluble PVP(Q)-C<sub>2</sub>H<sub>4</sub>OH polymers (MW 60,000 and 160,000). The resulting PVP(Q)-C<sub>2</sub>H<sub>4</sub>OH-Os(dmo-bpy)<sub>2</sub>Cl complexes were verified by UV-Vis, FT-IR, 1H NMR, SEM-EDS, and zeta potential analyses, confirming successful quaternization and osmium coordination with good dispersion stability. Electrochemical tests (cyclic voltammetry, multi-potential step, amperometry) demonstrated that electrodes with quaternized mediators showed greatly enhanced catalytic currents for glucose (0-20 mM), with sensitivities of 6.9791 (MW 60,000) and 6.6279 μA·mM<sup>-1</sup>·cm<sup>-2</sup> (MW 160,000), respectively, which were 6.6-10.3 times higher than those of non-quaternized polymers. Selectivity tests showed negligible interference from common species such as ascorbic acid, dopamine, uric acid, and serotonin. Continuous glucose monitoring (CGM) electrodes were fabricated by immobilizing the mediator and glucose dehydrogenase on silanized Au electrodes. SEM, scan rate, and impedance analyses confirmed stable binding. The modified electrodes showed strong linearity (R<sup>2</sup> = 0.992) and high sensitivity (2.56 μA·mM<sup>-1</sup>·cm<sup>-2</sup>), and good stability, maintaining ~82% activity for seven days. Human plasma testing validated accurate glucose detection (6.05 mM), consistent with physiological levels. Overall, quaternized PVP(Q) mediators significantly improved solubility and electron transfer, enabling the development of a stable, selective glucose sensor suitable for CGM applications.

PolymersVol. 17(21)
Hoseo University (KR), Dankook University (KR)
Hoseo University
Openalex Percentile: Top 69%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.