Image Processing Technology Applied to Fluorescent Rapid Tests for Influenza A and B Viruses

This study establishes a detection method based on image recognition to interpret and quantitatively analyze fluorescent rapid test kits for influenza. The method operates in a dark chamber equipped with a UV-LED, where the fluorescence of the test kit is excited by the UV-LED and subsequently captured using a camera module. The captured images are processed by segmenting the regions of interest (ROI), converting them to grayscale images, and analyzing the grayscale value distributions to identify the control (C) and test (T) line regions. By comparing the values of the C and T lines, the concentration is determined to achieve quantitative analysis. In the linearity validation experiments, the concentrations of influenza A (H1N1) specimens are 2, 4, 6, 8, and 10 ng/mL, achieving a coefficient of determination (R2) of 0.9923. For influenza B (Yamagata) specimens, concentrations of 6, 8, 10, 12.5, and 25 ng/mL resulted in an R2 of 0.9878. The established method enables the detection of both influenza A (H1N1) and influenza B (Yamagata), replacing visual qualitative interpretation with quantitative analysis. Currently, the detection method developed in this paper is designed for use exclusively in a dark chamber and is specifically applied to fluorescent rapid tests. It cannot be directly used with conventional colloidal gold-based rapid test reagents. In the future, the proposed detection approach could be integrated with neural networks to enable its application to non-fluorescent rapid test interpretation and to operate beyond the dark chamber environment, for example by utilizing smartphone imaging for result interpretation under normal lighting conditions.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-10-28
DOI
https://doi.org/10.3390/app152111523
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image Processing Technology Applied to Fluorescent Rapid Tests for Influenza A and B Viruses

Wen‐Fung Pan, Yu‐Cheng Lin, Wei-Chien Weng, Yulin Wu
Applied Sciences
Biosensors and Analytical Detection
article

Image Processing Technology Applied to Fluorescent Rapid Tests for Influenza A and B Viruses

Wen‐Fung Pan, Yu‐Cheng Lin, Wei-Chien Weng, Yulin Wu
article en

Abstract

This study establishes a detection method based on image recognition to interpret and quantitatively analyze fluorescent rapid test kits for influenza. The method operates in a dark chamber equipped with a UV-LED, where the fluorescence of the test kit is excited by the UV-LED and subsequently captured using a camera module. The captured images are processed by segmenting the regions of interest (ROI), converting them to grayscale images, and analyzing the grayscale value distributions to identify the control (C) and test (T) line regions. By comparing the values of the C and T lines, the concentration is determined to achieve quantitative analysis. In the linearity validation experiments, the concentrations of influenza A (H1N1) specimens are 2, 4, 6, 8, and 10 ng/mL, achieving a coefficient of determination (R2) of 0.9923. For influenza B (Yamagata) specimens, concentrations of 6, 8, 10, 12.5, and 25 ng/mL resulted in an R2 of 0.9878. The established method enables the detection of both influenza A (H1N1) and influenza B (Yamagata), replacing visual qualitative interpretation with quantitative analysis. Currently, the detection method developed in this paper is designed for use exclusively in a dark chamber and is specifically applied to fluorescent rapid tests. It cannot be directly used with conventional colloidal gold-based rapid test reagents. In the future, the proposed detection approach could be integrated with neural networks to enable its application to non-fluorescent rapid test interpretation and to operate beyond the dark chamber environment, for example by utilizing smartphone imaging for result interpretation under normal lighting conditions.

Applied SciencesVol. 15(21)
National Cheng Kung University (TW)
Openalex Percentile: Top 70%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Image Processing Technology Applied to Fluorescent Rapid Tests for Influenza A and B Viruses — Wen‐Fung Pan, Yu‐Cheng Lin, et al. · Applied Sciences (2025) | TGRS Research Map | TGRS