Pediatric Pacing from Proximal Right Ventricular Septum: Preserved Left Ventricular Systolic Function at Follow-Up

Chronic right ventricular (RV) pacing can impair left ventricular (LV) function. Non-fluoroscopic 3D-electroanatomic mapping (3D-EAM) allows targeted catheter navigation to septal sites close to the conduction system, reducing fluoroscopy exposure. This study evaluated whether 3D-EAM-guided pacing of the proximal RV septum (RVS) preserves LV contractility in pediatric patients with systemic LV and complete atrioventricular block (CAVB). We conducted a retrospective, single-center study. Electrocardiograms and echocardiograms obtained before implantation and during follow-up were analyzed for QRS duration, LV dimensions and systolic function: ejection fraction (EF), global longitudinal/circumferential strain (GLS/GCS), and rotation. Data are presented as median (25th-75th percentile). Statistical significance was set at P < 0.05. The cohort included 61 patients, aged 11.0 (8.0-14.0; full range 3-18) years: 9 of whom underwent non-selective His bundle pacing (NSHBP), 48 RVS, and 4 RV outflow septum pacing. All procedures were successful. Follow-up was 4 years (2-6), maximum 10 years. For all patients, the paced QRS duration was 118 ms (110-124) and remained stable. No significant differences in QRS duration or LV systolic function were observed between NSHBP and RVS. Echocardiographic indexes remained largely within normal limits. Patients with reduced LV systolic function at baseline improved during follow-up, while two patients demonstrated impaired function at longer follow-up. Lead dysfunction occurred more frequently with NSHBP than with RVS pacing, requiring lead repositioning or replacement. In pediatric patients with CAVB, 3D-EAM-guided pacing of the proximal RV septum near the conduction system preserved LV systolic function during follow-up.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2025-10-28
DOI
https://doi.org/10.1007/s00246-025-04072-4
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pediatric Pacing from Proximal Right Ventricular Septum: Preserved Left Ventricular Systolic Function at Follow-Up

Marta Campisi, Chiara Mizzon, Marianna Cicenia, Ilaria Tamburri et al.
1 citations
Pediatric Cardiology
Cardiac pacing and defibrillation studies
1.39
article

Pediatric Pacing from Proximal Right Ventricular Septum: Preserved Left Ventricular Systolic Function at Follow-Up

Marta Campisi, Chiara Mizzon, Marianna Cicenia, Ilaria Tamburri, Vincenzo Pazzano, Fabrizio Drago, Lucilla Ravà, Fabio Anselmo Saputo, Massimo Stefano Silvetti, Virginia Battista
article en
1 citations

Abstract

Chronic right ventricular (RV) pacing can impair left ventricular (LV) function. Non-fluoroscopic 3D-electroanatomic mapping (3D-EAM) allows targeted catheter navigation to septal sites close to the conduction system, reducing fluoroscopy exposure. This study evaluated whether 3D-EAM-guided pacing of the proximal RV septum (RVS) preserves LV contractility in pediatric patients with systemic LV and complete atrioventricular block (CAVB). We conducted a retrospective, single-center study. Electrocardiograms and echocardiograms obtained before implantation and during follow-up were analyzed for QRS duration, LV dimensions and systolic function: ejection fraction (EF), global longitudinal/circumferential strain (GLS/GCS), and rotation. Data are presented as median (25th-75th percentile). Statistical significance was set at P < 0.05. The cohort included 61 patients, aged 11.0 (8.0-14.0; full range 3-18) years: 9 of whom underwent non-selective His bundle pacing (NSHBP), 48 RVS, and 4 RV outflow septum pacing. All procedures were successful. Follow-up was 4 years (2-6), maximum 10 years. For all patients, the paced QRS duration was 118 ms (110-124) and remained stable. No significant differences in QRS duration or LV systolic function were observed between NSHBP and RVS. Echocardiographic indexes remained largely within normal limits. Patients with reduced LV systolic function at baseline improved during follow-up, while two patients demonstrated impaired function at longer follow-up. Lead dysfunction occurred more frequently with NSHBP than with RVS pacing, requiring lead repositioning or replacement. In pediatric patients with CAVB, 3D-EAM-guided pacing of the proximal RV septum near the conduction system preserved LV systolic function during follow-up.

Pediatric Cardiology
Bambino Gesù Children's Hospital (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Ministero della Salute
Openalex Percentile: Top 14%
Cardiac pacing and defibrillation studies
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.