Experimental investigations of internal macro-scale convection in the loose-fill wood fiber insulation layer of a full-scale wall element

• Internal macro-scale convection occurs in loose-fill wood fiber insulation. • 7 steady-state and 4 dynamic cases show onset of internal macro-scale convection. • Dynamic boundary conditions reduce the effect of internal macro-scale convection. • The effective U-value shows an increasing tendency with increasing temperature. With increasing restrictions on the energy efficiency of buildings, thicker insulation layers are installed in new and refurbished buildings to reduce heat losses. Previous studies have indicated that internal macro-scale convection cells can occur in thick porous insulation layers, decreasing the thermal performance of the envelope component. The focus of previous studies has been on horizontal insulation layers, most often composed of glass wool. Therefore, there is a lack of empirical data for loose-fill insulation and, in particular, bio-based materials, which have the potential of being more sustainable than conventional ones. The present investigation of this paper looks at the possibility of internal macro-scale convection inside loose-fill wood fiber insulation in a full-scale vertical wall element, with the modified Rayleigh number in the current investigation being between 20 and 45 and exhibiting internal convection in all cases. The experimental results show good agreement in terms of heat flux and temperature distribution with numerical simulations where the macro-scale convection is modelled explicitly. It also indicates that internal macro-scale convection can be modelled with existing building physics simulation tools, such as COMSOL. Finally, the internal macro-scale convection increases the effective U-value by up to 90 % for the highest temperature difference in steady-state conditions. This effect appears to diminish under dynamic boundary conditions, with a calculated effective U-value being within the uncertainty of the steady-state case with the lowest temperature difference, indicating that it might be less influential under real conditions.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-10-28
DOI
https://doi.org/10.1016/j.enbuild.2025.116646
Citations
1
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigations of internal macro-scale convection in the loose-fill wood fiber insulation layer of a full-scale wall element

Martin Veit, Hicham Johra, Rasmus Lund Jensen, Nikolaj Rask et al.
1 citations
Energy and Buildings
Hygrothermal properties of building materials
1.01
article

Experimental investigations of internal macro-scale convection in the loose-fill wood fiber insulation layer of a full-scale wall element

Martin Veit, Hicham Johra, Rasmus Lund Jensen, Nikolaj Rask, Simon M. Roesgaard
article en
1 citations

Abstract

• Internal macro-scale convection occurs in loose-fill wood fiber insulation. • 7 steady-state and 4 dynamic cases show onset of internal macro-scale convection. • Dynamic boundary conditions reduce the effect of internal macro-scale convection. • The effective U-value shows an increasing tendency with increasing temperature. With increasing restrictions on the energy efficiency of buildings, thicker insulation layers are installed in new and refurbished buildings to reduce heat losses. Previous studies have indicated that internal macro-scale convection cells can occur in thick porous insulation layers, decreasing the thermal performance of the envelope component. The focus of previous studies has been on horizontal insulation layers, most often composed of glass wool. Therefore, there is a lack of empirical data for loose-fill insulation and, in particular, bio-based materials, which have the potential of being more sustainable than conventional ones. The present investigation of this paper looks at the possibility of internal macro-scale convection inside loose-fill wood fiber insulation in a full-scale vertical wall element, with the modified Rayleigh number in the current investigation being between 20 and 45 and exhibiting internal convection in all cases. The experimental results show good agreement in terms of heat flux and temperature distribution with numerical simulations where the macro-scale convection is modelled explicitly. It also indicates that internal macro-scale convection can be modelled with existing building physics simulation tools, such as COMSOL. Finally, the internal macro-scale convection increases the effective U-value by up to 90 % for the highest temperature difference in steady-state conditions. This effect appears to diminish under dynamic boundary conditions, with a calculated effective U-value being within the uncertainty of the steady-state case with the lowest temperature difference, indicating that it might be less influential under real conditions.

Energy and BuildingsVol. 350
SINTEF (NO), Ghent University (BE), Slovenian National Building and Civil Engineering Institute (SI), Aalborg University (DK)
Openalex Percentile: Top 19%
Hygrothermal properties of building materials
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.