In Vivo 3D Liver Imaging at 7 T Using kT‐Point pTx Pulses and a 32‐Tx‐Channel Whole‐Body Radiofrequency Coil Array
At 7 T, a main challenge is the flip angle variations arising from the spatially inhomogeneous B<sub>1</sub> <sup>+</sup> transmit profiles of the RF coils. To address this problem, static pTx with local pTx body arrays has been used. However, for larger organs, such as the liver, local arrays provide insufficient homogeneity, and often dynamic pTx is needed. In this study, the benefits of a 32-Tx-channel remote array are shown. Relative channel-wise 3D B<sub>1</sub> <sup>+</sup> maps are acquired in free breathing in 11:38 min with a radial phase encoding (RPE) acquisition scheme in five healthy volunteers at 7 T. For each subject, an ROI is drawn manually covering the whole liver. The necessary number of k<sub>T</sub>-point pTx pulses is analyzed by comparing L-curves that depict the tradeoff between FA homogeneity and RF power for a large range of regularization parameters. For all subjects, no FA dropouts remain, and CV values under 17% can be achieved with magnitude and phase shimming. Two to three k<sub>T</sub>-points showed a good tradeoff between FA homogeneity and RF power. To analyze different channel numbers, a fixed phase between the channel-wise B<sub>1</sub> <sup>+</sup> maps is set to achieve 8, 16, or 20 B<sub>1</sub> <sup>+</sup> maps for shimming. The higher channel number showed superior shimming performance for static and dynamic pTx. Comparing 32 versus 8 individual channels, a 1.3- to 1.6-fold improvement in homogeneity can be found for the same RF power using phase shimming. With 32 Tx channels, static pTx shim and two k<sub>T</sub>-points were applied in vivo in free breathing with a 3D RPE GRE sequence with 1.4-mm isotropic resolution. The in vivo signal magnitudes of the small FA acquisitions showed good agreement with the predicted relative B<sub>1</sub> <sup>+</sup> maps while neglecting B<sub>0</sub> nonuniformity. In summary, this study shows the advantages of using a remote 32-Tx channel array for in vivo liver imaging at 7 T.
Authors
- Stephan Orzada (ORCID: https://orcid.org/0000-0001-9784-4354)
- Sebastian Schmitter (ORCID: https://orcid.org/0000-0003-4410-6790)
- Thomas M. Fiedler (ORCID: https://orcid.org/0000-0002-1556-375X)
- Simon Schmidt (ORCID: https://orcid.org/0000-0003-1835-4002)
- Mark E. Ladd (ORCID: https://orcid.org/0000-0002-4128-9440)
- Harald H. Quick (ORCID: https://orcid.org/0000-0001-7964-0219)
- Johannes A. Grimm (ORCID: https://orcid.org/0009-0001-1260-3613)
- Sebastian Dietrich (ORCID: https://orcid.org/0000-0002-1610-909X)
- Armin Michael Nagel (ORCID: https://orcid.org/0000-0003-0948-1421)
- Christoph Stefan Aigner (ORCID: https://orcid.org/0000-0003-3618-9610)
- Constantin Schorling
Institutions
- Erwin L. Hahn Institute for Magnetic Resonance Imaging (DE)
- Physikalisch-Technische Bundesanstalt (DE)
- University of Minnesota (US)
- German Cancer Research Center (DE)
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Heidelberg University (DE)
- Essen University Hospital (DE)
- Max Planck Institute for Human Development (DE)
- Resonance Research (United States) (US)
Publication Details
- Journal
- NMR in Biomedicine
- Published
- 2025-10-28
- DOI
- https://doi.org/10.1002/nbm.70170
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00