ZnIn <sub>2</sub> S <sub>4</sub> /g-C <sub>3</sub> N <sub>4</sub> heterojunction–enabled PEC–ECL sensing interface for quenching assay of fipronil

A ZnIn<sub>2</sub>S<sub>4</sub>/g-C<sub>3</sub>N<sub>4</sub> heterojunction-enabled dual-mode photoelectrochemical-electrochemiluminescent (PEC-ECL) biosensor was constructed for the quenching detection of fipronil, in which the inputs of the target fipronil triggered double-step catalytic hairpin assembly (CHA) circuits, leading to the introduction of a MnO<sub>2</sub> nanoflower (NF) quencher. Leveraging the excellent changes in the signals, this biosensor exhibited a wide linear range with a detection limit of 6.8 fM in PEC mode and 6.2 fM in ECL mode. Furthermore, it allowed for fipronil analysis in lettuce and egg samples, exhibiting excellent consistency with the standard method, which confirmed its potential for food safety monitoring.

Authors

Institutions

Publication Details

Journal
Chemical Communications
Published
2025-10-28
DOI
https://doi.org/10.1039/d5cc05727b
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ZnIn 2 S 4 /g-C 3 N 4 heterojunction–enabled PEC–ECL sensing interface for quenching assay of fipronil

Yao Song, Huanyu Cheng, Qiumei Feng, Po Wang et al.
Chemical Communications
Advanced biosensing and bioanalysis techniques
article

ZnIn 2 S 4 /g-C 3 N 4 heterojunction–enabled PEC–ECL sensing interface for quenching assay of fipronil

Yao Song, Huanyu Cheng, Qiumei Feng, Po Wang, Huan Yang
article en

Abstract

A ZnIn<sub>2</sub>S<sub>4</sub>/g-C<sub>3</sub>N<sub>4</sub> heterojunction-enabled dual-mode photoelectrochemical-electrochemiluminescent (PEC-ECL) biosensor was constructed for the quenching detection of fipronil, in which the inputs of the target fipronil triggered double-step catalytic hairpin assembly (CHA) circuits, leading to the introduction of a MnO<sub>2</sub> nanoflower (NF) quencher. Leveraging the excellent changes in the signals, this biosensor exhibited a wide linear range with a detection limit of 6.8 fM in PEC mode and 6.2 fM in ECL mode. Furthermore, it allowed for fipronil analysis in lettuce and egg samples, exhibiting excellent consistency with the standard method, which confirmed its potential for food safety monitoring.

Chemical CommunicationsVol. 62(15)
Jiangsu Normal University (CN), Pennsylvania State University (US)
Openalex Percentile: Top 72%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.