Estimating the modulation transfer function at natural structures in clinical CBCT images using the edge technique

In dental radiography, where fine details need to be recognizable, image quality and spatial resolution play an important role. This is particularly the case in 3D imaging (CBCT), because the radiation exposure is significantly higher compared with any 2D imaging method. The gold standard for measuring spatial resolution, and especially for relating it to contrast, is the measurement of the modulation transfer function (MTF). The usual procedure to obtain the MTF is to take a CBCT scan of a test phantom, which consists of different materials. The MTF is then measured at the interface of 2 materials. In this work, we propose an approach in which we determine the MTF in clinical CBCT scans at the boundary of physiological, implanted, or restored teeth, as well as surrounding tissue structures of different densities. It is assumed that all CBCTs inhibit some kind of interface between a radio-dense and radio-translucent area. Following the methodology used by the German standard DIN 6868-161, we developed our own numerical software for the computation of the MTF. The method enables a stable estimation of spatial resolution (MTF) in clinical CBCT images.

Authors

Institutions

Publication Details

Journal
Dentomaxillofacial Radiology
Published
2025-10-28
DOI
https://doi.org/10.1093/dmfr/twaf077
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating the modulation transfer function at natural structures in clinical CBCT images using the edge technique

Ralf Schulze, Christos Katsaros, Matthias C Bott
Dentomaxillofacial Radiology
Dental Radiography and Imaging
article

Estimating the modulation transfer function at natural structures in clinical CBCT images using the edge technique

Ralf Schulze, Christos Katsaros, Matthias C Bott
article en

Abstract

In dental radiography, where fine details need to be recognizable, image quality and spatial resolution play an important role. This is particularly the case in 3D imaging (CBCT), because the radiation exposure is significantly higher compared with any 2D imaging method. The gold standard for measuring spatial resolution, and especially for relating it to contrast, is the measurement of the modulation transfer function (MTF). The usual procedure to obtain the MTF is to take a CBCT scan of a test phantom, which consists of different materials. The MTF is then measured at the interface of 2 materials. In this work, we propose an approach in which we determine the MTF in clinical CBCT scans at the boundary of physiological, implanted, or restored teeth, as well as surrounding tissue structures of different densities. It is assumed that all CBCTs inhibit some kind of interface between a radio-dense and radio-translucent area. Following the methodology used by the German standard DIN 6868-161, we developed our own numerical software for the computation of the MTF. The method enables a stable estimation of spatial resolution (MTF) in clinical CBCT images.

Dentomaxillofacial RadiologyVol. 55(2)
University of Bern (CH), Bern University of Applied Sciences (CH)
Openalex Percentile: Top 57%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Estimating the modulation transfer function at natural structures in clinical CBCT images using the edge technique — Ralf Schulze, Christos Katsaros, et al. · Dentomaxillofacial Radiology (2025) | TGRS Research Map | TGRS