Brain Perfusion Scintigraphy in the Diagnostic Toolbox for the Confirmation of Brain Death: Practical Aspects and Examination Protocol

<b>Background:</b> In addition to clinical examinations, confirmatory investigations are frequently performed to determine brain death (BD). Among other perfusion tests, brain perfusion scintigraphy (BPS) has been shown to be a reliable tool for the detection of brain circulatory arrest, particularly in cases with inconclusive clinical status or potential pharmacological interactions. <b>Methods</b>: Evaluation for brain death included standardized clinical examinations by two experienced neuro-intensive medicine specialists, followed by ancillary brain perfusion tests. BPS with the lipophilic tracer <sup>99m</sup>Tc-hexamethylpropyleneamine oxime (HMPAO) was performed according to a standardized protocol. Imaging results, additional confirmatory test results, as well as clinical parameters were prospectively recorded. <b>Results:</b> BPS was performed in 30 patients (18 male, 12 female; median age 55.5 years, range 0.1-79.8 years). Eight patients underwent decompressive craniectomy (DC) prior to BD evaluation, three patients were supported by veno-arterial extracorporeal membrane oxygenation (vaECMO), and one patient by a left ventricular assist device (LVAD). The median interval between the initial brain-damaging event and BPS was 4.0 days (range 1-18 days). BPS demonstrated brain perfusion cessation in all patients. A concomitant single-photon emission computed tomography (SPECT) was required in one patient. There were no technical failures requiring a re-examination. <b>Conclusions:</b> BPS is a feasible, safe, and technically robust confirmatory test in BD diagnosis. BPS yielded unambiguous results, particularly in cases with inconclusive results of other ancillary tests, in neonates, young children and patients after DC. It is applicable to patients supported by LVAD and vaECMO.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-10-28
DOI
https://doi.org/10.3390/diagnostics15212734
Primary Topic
Organ Donation and Transplantation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Brain Perfusion Scintigraphy in the Diagnostic Toolbox for the Confirmation of Brain Death: Practical Aspects and Examination Protocol

A. Gunkel, Michael Fritzenwanger, Robert Drescher, Albrecht Günther et al.
Diagnostics
Organ Donation and Transplantation
article

Brain Perfusion Scintigraphy in the Diagnostic Toolbox for the Confirmation of Brain Death: Practical Aspects and Examination Protocol

A. Gunkel, Michael Fritzenwanger, Robert Drescher, Albrecht Günther, Dirk Brämer, Martin G. Freesmeyer, Anke Werner, Claus Doerfel, Christian Geis, Thomas Winkens, Martin Bräuer
article en

Abstract

<b>Background:</b> In addition to clinical examinations, confirmatory investigations are frequently performed to determine brain death (BD). Among other perfusion tests, brain perfusion scintigraphy (BPS) has been shown to be a reliable tool for the detection of brain circulatory arrest, particularly in cases with inconclusive clinical status or potential pharmacological interactions. <b>Methods</b>: Evaluation for brain death included standardized clinical examinations by two experienced neuro-intensive medicine specialists, followed by ancillary brain perfusion tests. BPS with the lipophilic tracer <sup>99m</sup>Tc-hexamethylpropyleneamine oxime (HMPAO) was performed according to a standardized protocol. Imaging results, additional confirmatory test results, as well as clinical parameters were prospectively recorded. <b>Results:</b> BPS was performed in 30 patients (18 male, 12 female; median age 55.5 years, range 0.1-79.8 years). Eight patients underwent decompressive craniectomy (DC) prior to BD evaluation, three patients were supported by veno-arterial extracorporeal membrane oxygenation (vaECMO), and one patient by a left ventricular assist device (LVAD). The median interval between the initial brain-damaging event and BPS was 4.0 days (range 1-18 days). BPS demonstrated brain perfusion cessation in all patients. A concomitant single-photon emission computed tomography (SPECT) was required in one patient. There were no technical failures requiring a re-examination. <b>Conclusions:</b> BPS is a feasible, safe, and technically robust confirmatory test in BD diagnosis. BPS yielded unambiguous results, particularly in cases with inconclusive results of other ancillary tests, in neonates, young children and patients after DC. It is applicable to patients supported by LVAD and vaECMO.

DiagnosticsVol. 15(21)
Jena University Hospital (DE)
Openalex Percentile: Top 59%
Organ Donation and Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.