Optimization of the mirror mounting structure for a reflective star tracker based on integrated analysis of line-of-sight thermal stability error

This paper investigates the thermal drift of the line-of-sight (LOS) resulting from temperature fluctuations during the on-orbit operation of a large-aperture, long-focal-length off-axis reflective star tracker. It aims to develop optimization strategies to improve thermal stability and LOS accuracy. A tolerance analysis of the optical system was first performed to quantify the impact of each optical component on LOS variation, with a specific focus on the primary, secondary, and tertiary mirrors. Subsequently, an LOS sensitivity matrix was constructed to correlate structural displacements with optical image point deviations. Based on this, the flexible support structures of the mirrors were sequentially optimized, resulting in a configuration that effectively reduces thermal drift. The results indicate that, following optimization, the LOS thermal drift angle decreased from 0.03499<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i> to 0.02435<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i> under a 5°C temperature increase, yielding a 30.4% reduction. The measured LOS thermal drift angle was 0.02641<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i>, deviating by only 8.46% from the simulation result. Surface figure measurements showed that the respective surface errors of the primary, secondary, and tertiary mirrors were 0.015<i>λ</i>,0.017<i>λ</i>, and 0.014<i>λ</i>, all satisfying the star tracker's technical specification (<i>R</i><i>M</i><i>S</i>≤<i>λ</i>/50). Wavefront aberration measurements yielded RMS values of 0.066<i>λ</i>,0.068<i>λ</i>,0.073<i>λ</i>,0.072<i>λ</i>, and 0.069<i>λ</i> across five fields of view, conforming to the imaging system's technical specification (<i>R</i><i>M</i><i>S</i>≤1/14<i>λ</i>). The proposed optimization strategy enhances thermal stability, mitigates LOS thermal drift, and ensures that the final design fulfills the high-precision attitude determination requirements for space applications.

Authors

Publication Details

Journal
Applied Optics
Published
2025-10-28
DOI
https://doi.org/10.1364/ao.577659
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the mirror mounting structure for a reflective star tracker based on integrated analysis of line-of-sight thermal stability error

Zhao Qin, Zongxuan Li, X. Yang, Yongsheng Gao et al.
Applied Optics
Inertial Sensor and Navigation
article

Optimization of the mirror mounting structure for a reflective star tracker based on integrated analysis of line-of-sight thermal stability error

Zhao Qin, Zongxuan Li, X. Yang, Yongsheng Gao, Lin Li, Jingping Ning
article en

Abstract

This paper investigates the thermal drift of the line-of-sight (LOS) resulting from temperature fluctuations during the on-orbit operation of a large-aperture, long-focal-length off-axis reflective star tracker. It aims to develop optimization strategies to improve thermal stability and LOS accuracy. A tolerance analysis of the optical system was first performed to quantify the impact of each optical component on LOS variation, with a specific focus on the primary, secondary, and tertiary mirrors. Subsequently, an LOS sensitivity matrix was constructed to correlate structural displacements with optical image point deviations. Based on this, the flexible support structures of the mirrors were sequentially optimized, resulting in a configuration that effectively reduces thermal drift. The results indicate that, following optimization, the LOS thermal drift angle decreased from 0.03499<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i> to 0.02435<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i> under a 5°C temperature increase, yielding a 30.4% reduction. The measured LOS thermal drift angle was 0.02641<sup><i>'</i><i>'</i></sup>/<sup>∘</sup><i>C</i>, deviating by only 8.46% from the simulation result. Surface figure measurements showed that the respective surface errors of the primary, secondary, and tertiary mirrors were 0.015<i>λ</i>,0.017<i>λ</i>, and 0.014<i>λ</i>, all satisfying the star tracker's technical specification (<i>R</i><i>M</i><i>S</i>≤<i>λ</i>/50). Wavefront aberration measurements yielded RMS values of 0.066<i>λ</i>,0.068<i>λ</i>,0.073<i>λ</i>,0.072<i>λ</i>, and 0.069<i>λ</i> across five fields of view, conforming to the imaging system's technical specification (<i>R</i><i>M</i><i>S</i>≤1/14<i>λ</i>). The proposed optimization strategy enhances thermal stability, mitigates LOS thermal drift, and ensures that the final design fulfills the high-precision attitude determination requirements for space applications.

Applied OpticsVol. 64(33)
Openalex Percentile: Top 57%
Inertial Sensor and Navigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.