Clinical evaluation of 3D-printed templates for accurate and safe mini-screw implantation

To develop mini-screw templates using three-dimensional (3D) printing technology to prevent root damage during implantation, and to evaluate the accuracy and safety of the implantation process. Thirteen patients requiring mini-screw implantation between the maxillary second premolar and first molar were recruited for this study. A total of 21 mini-screws were placed in vivo using patient-specific mini-screw templates designed with manipulation software. Following implantation, cone-beam computed tomography (CBCT) scans were obtained. The postoperative CBCT data were superimposed onto the preoperative scans using a correntropy-based registration algorithm to assess implant positioning. The accuracy and safety of mini-screw placement under the guidance of the 3D-printed templates were subsequently evaluated. The mean 3D deviation at the mini-screw tail was 1.10 ± 0.48 mm. The deviations in the coronal, sagittal, and vertical directions were 0.31 ± 0.28 mm, 0.38 ± 0.29 mm, and 0.88 ± 0.51 mm, respectively. The actual deviation (0.39 ± 0.30 mm) was significantly smaller than the permitted deviation (1.04 ± 0.45 mm), with the difference reaching statistical significance ( P < 0.05). The 3D-printed mini-screw templates demonstrated high accuracy and safety in guiding mini-screw implantation between the maxillary second premolar and first molar. The actual deviations observed were significantly smaller than the clinically accepted limits, indicating reliable positional control and minimized risk of root damage. 3D-printed templates significantly enhance the precision and predictability of orthodontic mini-screw placement and provide a clinically reliable technique. • A correntropy-based ICP algorithm was applied to improve CBCT registration accuracy. • Micro-CT scanned miniscrew models replaced simplified geometries for more precise planning. • A surgical template adaptable to various clinical scenarios was developed. • High placement accuracy was achieved with no significant difference between left and right sides. • The workflow minimized deviations while maintaining safety from root contact.

Authors

Institutions

Publication Details

Journal
Translational dental research.
Published
2025-10-01
DOI
https://doi.org/10.1016/j.tdr.2025.100053
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical evaluation of 3D-printed templates for accurate and safe mini-screw implantation

Huan Jin, Badr Sultan Saif, Qingnan Mou, Shaoyi Du et al.
Translational dental research.
Dental Implant Techniques and Outcomes
article

Clinical evaluation of 3D-printed templates for accurate and safe mini-screw implantation

Huan Jin, Badr Sultan Saif, Qingnan Mou, Shaoyi Du, Hui Yang, Yuying Liu, Yu-cheng Guo, Mei Li, Yuxia Hou, Wenqing Bu, Yu Tang
article en

Abstract

To develop mini-screw templates using three-dimensional (3D) printing technology to prevent root damage during implantation, and to evaluate the accuracy and safety of the implantation process. Thirteen patients requiring mini-screw implantation between the maxillary second premolar and first molar were recruited for this study. A total of 21 mini-screws were placed in vivo using patient-specific mini-screw templates designed with manipulation software. Following implantation, cone-beam computed tomography (CBCT) scans were obtained. The postoperative CBCT data were superimposed onto the preoperative scans using a correntropy-based registration algorithm to assess implant positioning. The accuracy and safety of mini-screw placement under the guidance of the 3D-printed templates were subsequently evaluated. The mean 3D deviation at the mini-screw tail was 1.10 ± 0.48 mm. The deviations in the coronal, sagittal, and vertical directions were 0.31 ± 0.28 mm, 0.38 ± 0.29 mm, and 0.88 ± 0.51 mm, respectively. The actual deviation (0.39 ± 0.30 mm) was significantly smaller than the permitted deviation (1.04 ± 0.45 mm), with the difference reaching statistical significance ( P < 0.05). The 3D-printed mini-screw templates demonstrated high accuracy and safety in guiding mini-screw implantation between the maxillary second premolar and first molar. The actual deviations observed were significantly smaller than the clinically accepted limits, indicating reliable positional control and minimized risk of root damage. 3D-printed templates significantly enhance the precision and predictability of orthodontic mini-screw placement and provide a clinically reliable technique. • A correntropy-based ICP algorithm was applied to improve CBCT registration accuracy. • Micro-CT scanned miniscrew models replaced simplified geometries for more precise planning. • A surgical template adaptable to various clinical scenarios was developed. • High placement accuracy was achieved with no significant difference between left and right sides. • The workflow minimized deviations while maintaining safety from root contact.

Translational dental research.Vol. 1(4)
University of Otago (NZ), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 57%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.