Parametric evaluation and biomechanical assessment of a curved biodegradable ZK60 locking plate for femoral shaft fractures using finite element analysis

This study evaluates the biomechanical performance of a novel curved biodegradable ZK60 magnesium alloy locking plate for plate osteosynthesis in midshaft femoral fractures classified as AO/ASIF 32-A3 (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of Internal Fixation). Current metallic implants are associated with complications such as stress shielding, the need for secondary surgery, and limited support for biological healing. Biodegradable options offer promising solutions but remain insufficiently studied, especially regarding curved plate designs. This work addresses that gap by systematically assessing how plate thickness and curvature influence fracture stability. Finite element analysis (FEA) was performed under physiological loading of 700 N simulating a single-leg stance. Ten configurations were modeled, combining two thicknesses (4 and 6 mm) with five bending angles (0, 5, 10, 15, and 20°). A 5 mm fracture gap was simulated, and all constructs were fixed with bicortical locking screws. Axial stiffness and total deformation were calculated and compared with those of an intact femur. Results indicated that both increased plate thickness and curvature enhanced construct performance. The 6 mm plate bent at 20° showed the highest stiffness (2328.9 N/mm) and lowest deformation (0.3007 mm), representing a 6.6% increase in stiffness and 5.8% reduction in deformation compared with the flat counterpart. Similar trends were observed for the 4 mm plate. The evaluated designs achieved 23.8–25.4% of intact femur stiffness, aligning with the biomechanical window that promotes callus formation through controlled micromotion. Curved configurations also improved load transfer and screw alignment. Among the tested designs, the 6 mm plate bent at 15°–20° demonstrates the most favorable biomechanical characteristics for potential clinical translation.

Authors

Institutions

Publication Details

Journal
Engineering and Technology Journal
Published
2025-10-28
DOI
https://doi.org/10.30684/etj.2025.162401.1983
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parametric evaluation and biomechanical assessment of a curved biodegradable ZK60 locking plate for femoral shaft fractures using finite element analysis

Ali T. Jasim, Jenan S. Kashan, Aseel Abed
Engineering and Technology Journal
Bone fractures and treatments
article

Parametric evaluation and biomechanical assessment of a curved biodegradable ZK60 locking plate for femoral shaft fractures using finite element analysis

Ali T. Jasim, Jenan S. Kashan, Aseel Abed
article en

Abstract

This study evaluates the biomechanical performance of a novel curved biodegradable ZK60 magnesium alloy locking plate for plate osteosynthesis in midshaft femoral fractures classified as AO/ASIF 32-A3 (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of Internal Fixation). Current metallic implants are associated with complications such as stress shielding, the need for secondary surgery, and limited support for biological healing. Biodegradable options offer promising solutions but remain insufficiently studied, especially regarding curved plate designs. This work addresses that gap by systematically assessing how plate thickness and curvature influence fracture stability. Finite element analysis (FEA) was performed under physiological loading of 700 N simulating a single-leg stance. Ten configurations were modeled, combining two thicknesses (4 and 6 mm) with five bending angles (0, 5, 10, 15, and 20°). A 5 mm fracture gap was simulated, and all constructs were fixed with bicortical locking screws. Axial stiffness and total deformation were calculated and compared with those of an intact femur. Results indicated that both increased plate thickness and curvature enhanced construct performance. The 6 mm plate bent at 20° showed the highest stiffness (2328.9 N/mm) and lowest deformation (0.3007 mm), representing a 6.6% increase in stiffness and 5.8% reduction in deformation compared with the flat counterpart. Similar trends were observed for the 4 mm plate. The evaluated designs achieved 23.8–25.4% of intact femur stiffness, aligning with the biomechanical window that promotes callus formation through controlled micromotion. Curved configurations also improved load transfer and screw alignment. Among the tested designs, the 6 mm plate bent at 15°–20° demonstrates the most favorable biomechanical characteristics for potential clinical translation.

Engineering and Technology JournalVol. 0(0)
University of Technology - Iraq (IQ), Iraqi University (IQ)
Openalex Percentile: Top 58%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.