Polyelectrolyte Multilayer Coatings As a Tunable Tool to Control Inflammatory Response to Biomaterials in Vitro

The immune response to implanted medical devices can impact their performance and longevity in the body. Instead of designing implants to produce the desired immune responses, this might more easily be achieved with the use of surface modification technology, which can alter the biological profile of the implant without compromising function or performance. In the present study, we generated two polyelectrolyte (PE) multilayer (PEM) coatings from polystyrenesulfonate (PSS) and poly(allylamine hydrochloride) (PAH). These two coatings had identical chemical compositions, but the wettability and surface charge were adjusted by altering the deposition conditions. Testing the immune response to these coatings <i>in vitro</i> showed that the differing surface properties of the two coatings impacted morphology (circularity) and actin-cytoskeleton formation (podosomal structures) of THP-1-derived macrophages. We furthermore observed a substantial pro-inflammatory response toward the coating with the medium hydrophilic properties and moderate surface charge density (PEM_MH), while the highly hydrophilic and strongly negatively charged coating (PEM_HH) resulted in a much milder inflammatory response. Application of the latter coating to implant materials that elicited pronounced inflammatory responses resulted in a substantial reduction in the inflammatory response observed. This was validated by using blood-derived primary human immune cells. The dampened pro-inflammatory effect could be observed with two different materials: polymer membranes and titanium. Our results highlight the promise of pure PEM coatings without any additional substances as a tool to tune the immune response toward established medical implants.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2025-10-28
DOI
https://doi.org/10.1021/acsabm.5c01021
Primary Topic
Polymer Surface Interaction Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polyelectrolyte Multilayer Coatings As a Tunable Tool to Control Inflammatory Response to Biomaterials in Vitro

Nicole Schneiderhan‐Marra, Dagmar Martin, Elsa Arefaine, Sören Segan et al.
ACS Applied Bio Materials
Polymer Surface Interaction Studies
article

Polyelectrolyte Multilayer Coatings As a Tunable Tool to Control Inflammatory Response to Biomaterials in Vitro

Nicole Schneiderhan‐Marra, Dagmar Martin, Elsa Arefaine, Sören Segan, Tonya Andreeva, Hanna Hartmann, Karin Gerlach, Luisa Pickarski, Meike Jakobi, Christopher Shipp, Ulrich Rothbauer, Claus Burkhardt, Rumen Krastev, Florian Rosahl, Laura Strano
article en

Abstract

The immune response to implanted medical devices can impact their performance and longevity in the body. Instead of designing implants to produce the desired immune responses, this might more easily be achieved with the use of surface modification technology, which can alter the biological profile of the implant without compromising function or performance. In the present study, we generated two polyelectrolyte (PE) multilayer (PEM) coatings from polystyrenesulfonate (PSS) and poly(allylamine hydrochloride) (PAH). These two coatings had identical chemical compositions, but the wettability and surface charge were adjusted by altering the deposition conditions. Testing the immune response to these coatings <i>in vitro</i> showed that the differing surface properties of the two coatings impacted morphology (circularity) and actin-cytoskeleton formation (podosomal structures) of THP-1-derived macrophages. We furthermore observed a substantial pro-inflammatory response toward the coating with the medium hydrophilic properties and moderate surface charge density (PEM_MH), while the highly hydrophilic and strongly negatively charged coating (PEM_HH) resulted in a much milder inflammatory response. Application of the latter coating to implant materials that elicited pronounced inflammatory responses resulted in a substantial reduction in the inflammatory response observed. This was validated by using blood-derived primary human immune cells. The dampened pro-inflammatory effect could be observed with two different materials: polymer membranes and titanium. Our results highlight the promise of pure PEM coatings without any additional substances as a tool to tune the immune response toward established medical implants.

ACS Applied Bio MaterialsVol. 8(11)
Natural and Medical Sciences Institute (DE), Pharmaceutical Biotechnology (Czechia) (CZ), Reutlingen University (DE), University of Tübingen (DE)
Openalex Percentile: Top 70%
Polymer Surface Interaction Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.