Evaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence

Traditional protocols utilizing optically stimulated luminescence (OSL) and thermoluminescence (TL) of surface-mounted devices (SMDs) for retrospective dosimetry have demonstrated promising results, but limitations in sensitivity, especially for a limited number of SMD components, and small sample sizes, have prompted the exploration of alternative methods. The red thermoluminescence (RTL) protocol has emerged as a promising alternative, taking advantage of the strong TL emission of SMD components in the near-infrared spectral range. The present study investigates the dosimetric performance of red thermoluminescence (TL) emission from surface-mounted devices (SMDs) and its potential for use in accident dosimetry. Key characteristics, such as intrinsic zero-dose signal, signal reproducibility, dose-response relationship, signal stability, and a dose recovery test, were systematically analysed. An irradiation experiment was conducted in which SMDs were exposed to 6 MV X-rays using LINAC, and subsequent dose reconstruction was carried out employing the RTL protocol. The experiments demonstrated that a new RTL protocol yields promising signal intensities, and successful dose reconstruction was achieved even after delayed readout, with fading corrections applied. Dose estimates obtained from single SMD resistors, both reference components and those extracted from a smartwatch, showed good agreement with reference dosimeters, with overestimations between 5 % and 24 %. These findings confirm that the RTL method includes sufficient sensitivity and the ability to analyse very limited sample quantities, particularly in scenarios where signal sensitivity is critical. • Promising dosimetric properties with strong signal intensity obtained for a single SMD • Dose recovery test yielded accurate results • Irradiation experiment confirms RTL protocol as viable alternative

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2025-10-28
DOI
https://doi.org/10.1016/j.radmeas.2025.107548
Citations
1
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence

Michael Discher, C. Bassinet, Hyoungtaek Kim
1 citations
Radiation Measurements
Luminescence Properties of Advanced Materials
0.52
article

Evaluating SMD resistors in electronic devices as accident dosimeters using red thermoluminescence

Michael Discher, C. Bassinet, Hyoungtaek Kim
article en
1 citations

Abstract

Traditional protocols utilizing optically stimulated luminescence (OSL) and thermoluminescence (TL) of surface-mounted devices (SMDs) for retrospective dosimetry have demonstrated promising results, but limitations in sensitivity, especially for a limited number of SMD components, and small sample sizes, have prompted the exploration of alternative methods. The red thermoluminescence (RTL) protocol has emerged as a promising alternative, taking advantage of the strong TL emission of SMD components in the near-infrared spectral range. The present study investigates the dosimetric performance of red thermoluminescence (TL) emission from surface-mounted devices (SMDs) and its potential for use in accident dosimetry. Key characteristics, such as intrinsic zero-dose signal, signal reproducibility, dose-response relationship, signal stability, and a dose recovery test, were systematically analysed. An irradiation experiment was conducted in which SMDs were exposed to 6 MV X-rays using LINAC, and subsequent dose reconstruction was carried out employing the RTL protocol. The experiments demonstrated that a new RTL protocol yields promising signal intensities, and successful dose reconstruction was achieved even after delayed readout, with fading corrections applied. Dose estimates obtained from single SMD resistors, both reference components and those extracted from a smartwatch, showed good agreement with reference dosimeters, with overestimations between 5 % and 24 %. These findings confirm that the RTL method includes sufficient sensitivity and the ability to analyse very limited sample quantities, particularly in scenarios where signal sensitivity is critical. • Promising dosimetric properties with strong signal intensity obtained for a single SMD • Dose recovery test yielded accurate results • Irradiation experiment confirms RTL protocol as viable alternative

Radiation MeasurementsVol. 190
Institut de Radioprotection et de Sûreté Nucléaire (FR), Korea Atomic Energy Research Institute (KR), University of Salzburg (AT), Autorité de sûreté nucléaire et de radioprotection (FR)
Openalex Percentile: Top 31%
Luminescence Properties of Advanced Materials
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.