Temperature drift suppression and measurement dead zone elimination in differential MEMS resonant accelerometers using dual-mode operating method

This paper proposes a differential mode measurement and control system (DMCS) for differential MEMS resonant accelerometer (DMRA), which operates the differential resonators of the DMRA at different vibration modes. Unlike traditional DMRA, the first resonator of the differential resonator operates in the first-order mode (R1M1), and the second resonator operates in the second-order mode (R2M2). Within the measurement range of DMRA, the frequencies of the two resonators will not cross, so there will be no mutual interference. This ensures the structural symmetry of the DMRA while avoiding the measurement dead zone phenomenon caused by the coupling of the differential vibration beam at similar resonant frequencies. The structural symmetry of the differential resonator ensures good temperature consistency of the differential vibration beam, and the consistency of the temperature frequency coefficient matches well, which enables the differential resonator to strongly suppress the temperature-induced common-mode effects. During the temperature cycling process between -20 °C and 80 °C, the equivalent acceleration drift of R1M1 and R2M2 were 341.6 mg and 414.6 mg, respectively. After using the differential temperature compensation algorithm, the equivalent acceleration drift was reduced to 1.19 mg. The minimum Allan variance measured statically at room temperature decreased from 1.42 μ[email protected] s for R1M1 and 1.52 μ[email protected] s for R2M2 to 0.23 μ[email protected] s, indicating a significant improvement in the long-term stability of DMRA. In addition, the differential measuring method also eliminated common mode ambient noise in low frequency range, ultimately achieving a noise level of 220 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>ng</mml:mi> <mml:mo>/</mml:mo> <mml:msqrt><mml:mrow><mml:mi>Hz</mml:mi></mml:mrow> </mml:msqrt> </mml:mrow> </mml:math> @(0.2-0.8 Hz) for a prototype device with a measurement range exceeding ±5 g.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-10-28
DOI
https://doi.org/10.1038/s41378-025-01022-1
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature drift suppression and measurement dead zone elimination in differential MEMS resonant accelerometers using dual-mode operating method

Xudong Zou, Kunfeng Wang, Zheng Wang, Zhaoyang Zhai et al.
Microsystems & Nanoengineering
Advanced MEMS and NEMS Technologies
article

Temperature drift suppression and measurement dead zone elimination in differential MEMS resonant accelerometers using dual-mode operating method

Xudong Zou, Kunfeng Wang, Zheng Wang, Zhaoyang Zhai, Liangbo Ma, Xiaorui Bie, Bingchen Zhu, Wuhao Yang
article en

Abstract

This paper proposes a differential mode measurement and control system (DMCS) for differential MEMS resonant accelerometer (DMRA), which operates the differential resonators of the DMRA at different vibration modes. Unlike traditional DMRA, the first resonator of the differential resonator operates in the first-order mode (R1M1), and the second resonator operates in the second-order mode (R2M2). Within the measurement range of DMRA, the frequencies of the two resonators will not cross, so there will be no mutual interference. This ensures the structural symmetry of the DMRA while avoiding the measurement dead zone phenomenon caused by the coupling of the differential vibration beam at similar resonant frequencies. The structural symmetry of the differential resonator ensures good temperature consistency of the differential vibration beam, and the consistency of the temperature frequency coefficient matches well, which enables the differential resonator to strongly suppress the temperature-induced common-mode effects. During the temperature cycling process between -20 °C and 80 °C, the equivalent acceleration drift of R1M1 and R2M2 were 341.6 mg and 414.6 mg, respectively. After using the differential temperature compensation algorithm, the equivalent acceleration drift was reduced to 1.19 mg. The minimum Allan variance measured statically at room temperature decreased from 1.42 μ[email protected] s for R1M1 and 1.52 μ[email protected] s for R2M2 to 0.23 μ[email protected] s, indicating a significant improvement in the long-term stability of DMRA. In addition, the differential measuring method also eliminated common mode ambient noise in low frequency range, ultimately achieving a noise level of 220 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>ng</mml:mi> <mml:mo>/</mml:mo> <mml:msqrt><mml:mrow><mml:mi>Hz</mml:mi></mml:mrow> </mml:msqrt> </mml:mrow> </mml:math> @(0.2-0.8 Hz) for a prototype device with a measurement range exceeding ±5 g.

Microsystems & NanoengineeringVol. 11(1)
Chinese Academy of Sciences (CN), State Key Laboratory of Transducer Technology (CN), Institute of Electronics (CN), Aerospace Information Research Institute (CN), University of Chinese Academy of Sciences (CN)
Chinese Academy of Sciences, Natural Science Foundation of Shandong Province, National Key Research and Development Program of China
Openalex Percentile: Top 69%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.