Dual-arc VMAT machine parameter optimization for localized prostate cancer using deep reinforcement learning

<i>Objective.</i>To develop and evaluate a deep reinforcement learning (RL) framework for rapid and automatic machine parameter optimization of volumetric modulated arc therapy (VMAT) treatment plans for localized prostate cancer.<i>Approach.</i>A multi-task policy network combining convolution and long short-term memory was trained to sequentially predict the set of actions on the dose rate and multi-leaf collimator positions over the range of two arcs. The network uses as input the cumulative dose grid at the current gantry angle, contours of the planning target volume (PTV) and organs at risk, and the set of machine parameters at all preceding gantry angles. The method was evaluated on a set of 15 localized prostate cancer patients for a prescription dose of 60 Gy in 20 fractions. For each case, the final state dose distribution was compared against clinical plans. For seamless integration with the clinical workflow, the proposed model was integrated into a clinical treatment planning system (TPS), enabling dosimetric review and final plan adjustments.<i>Main results.</i>The RL framework produced deliverable dual-arc VMAT plans in an average of 20.7 ± 5.0 s over the test set. Dosimetric comparison to clinical plans showed no statistically significant differences for the mean rectum dose as well as for the bladder V6160 Gy, indicating that the RL model was as efficient in sparing these structures as human planners. While the approach showed limitations in terms of PTV coverage and maximum body dose, our proposed integration to TPS showed the RL plans could be automatically refined to clinical quality in an additional 83.8 ± 7.2 s.<i>Significance.</i>The accuracy and fast run time of the approach show the potential of the framework to significantly streamline VMAT treatment planning and enable adaptive radiation therapy.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-10-27
DOI
https://doi.org/10.1088/1361-6560/ae1803
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-arc VMAT machine parameter optimization for localized prostate cancer using deep reinforcement learning

Lina Mekki, William T. Hrinivich, Junghoon Lee
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Dual-arc VMAT machine parameter optimization for localized prostate cancer using deep reinforcement learning

Lina Mekki, William T. Hrinivich, Junghoon Lee
article en

Abstract

<i>Objective.</i>To develop and evaluate a deep reinforcement learning (RL) framework for rapid and automatic machine parameter optimization of volumetric modulated arc therapy (VMAT) treatment plans for localized prostate cancer.<i>Approach.</i>A multi-task policy network combining convolution and long short-term memory was trained to sequentially predict the set of actions on the dose rate and multi-leaf collimator positions over the range of two arcs. The network uses as input the cumulative dose grid at the current gantry angle, contours of the planning target volume (PTV) and organs at risk, and the set of machine parameters at all preceding gantry angles. The method was evaluated on a set of 15 localized prostate cancer patients for a prescription dose of 60 Gy in 20 fractions. For each case, the final state dose distribution was compared against clinical plans. For seamless integration with the clinical workflow, the proposed model was integrated into a clinical treatment planning system (TPS), enabling dosimetric review and final plan adjustments.<i>Main results.</i>The RL framework produced deliverable dual-arc VMAT plans in an average of 20.7 ± 5.0 s over the test set. Dosimetric comparison to clinical plans showed no statistically significant differences for the mean rectum dose as well as for the bladder V6160 Gy, indicating that the RL model was as efficient in sparing these structures as human planners. While the approach showed limitations in terms of PTV coverage and maximum body dose, our proposed integration to TPS showed the RL plans could be automatically refined to clinical quality in an additional 83.8 ± 7.2 s.<i>Significance.</i>The accuracy and fast run time of the approach show the potential of the framework to significantly streamline VMAT treatment planning and enable adaptive radiation therapy.

Physics in Medicine and BiologyVol. 70(22)
Johns Hopkins University (US), Johns Hopkins Medicine (US)
Openalex Percentile: Top 59%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.