Comparison of position reconstructions and resolutions obtained by linear and logarithmic weighting methods for a LYSO matrix
In this study, position resolution calculations are presented for the lutetium-yttrium oxyorthosilicate (LYSO) crystal, which has recently been proposed for many high energy physics experiments due to its advantages. For this purpose, a module consisting of nine LYSO crystals in the form of a 3 × 3 matrix has been designed. Two methods have been studied to determine the impact position of a particle hitting the crystal: linear weighting and logarithmic weighting. The dependence of position resolution on the angle of the incident particle and the cross section of the crystal was examined using the Geant4 simulation code.
Authors
- F. Kocak (ORCID: https://orcid.org/0000-0002-4756-9988)
- M. F. O. Yahya
Institutions
- Bursa Uludağ Üni̇versi̇tesi̇ (TR)
- University of Nyala (SD)
Publication Details
- Journal
- Nuclear Physics B
- Published
- 2025-10-27
- DOI
- https://doi.org/10.1016/j.nuclphysb.2025.117171
- Primary Topic
- Electromagnetic Scattering and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00