A CRISPR-Cas12a Fluorescent Aptasensor for Point-of-Care Drug Concentration Detection: A Synergistic Regulation by DNA Aptamer and RNA Blocker

The combination of CRISPR-Cas12a with aptamers can potentially improve the sensitivity, specificity, and speed of non-nucleic acid target detection. Nevertheless, current CRISPR-Cas12a aptasensors, solely dependent on aptamer affinity and overlooking the enzymatic regulation of CRISPR-Cas12a, may produce false-positive signals. We proposed a CRISPR-Cas12a aptasensor synergistically regulated by an aptamer and RNA, which incorporated aptamer-mediated drug recognition and CRISPR-powered signal amplification in a one-pot format. Herein, a regulatory RNA probe synergized with the conformational switching of a drug-induced aptamer, enabling precise regulation of Cas12a trans-cleavage activity via toehold-mediated strand displacement (TMSD). This dual regulatory mechanism transformed the aptamer-activated CRISPR-Cas12a sensing process into a TMSD-driven conditional reaction, avoiding false-positive signals and thus achieving better detection performance with a lower detection limit. With the vancomycin (VCM) aptamer as a model, the aptasensor can detect VCM within 30 min from 2% serum, 1% synovial fluid, and 1% cerebrospinal fluid, with a detection limit of 13.62, 7.56, and 6.75 nM, respectively. The proposed aptasensor was incorporated into a custom 3D-printed portable fluorometer and underwent clinical validation in 22 VCM serum samples, reporting no significant difference when compared with the enzyme-multiplied immunoassay technique, confirming the reliability for point-of-care quantification. It further received cross-validation with a quinine aptamer, suggesting universality [a linear range of 10-250 nM (<i>R</i><sup>2</sup> = 0.985) and a detection limit of 0.42 nM]. By integration of aptamer selectivity with CRISPR programmability, this work presents a novel robust biosensing paradigm for point-of-care drug concentration detection.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-27
DOI
https://doi.org/10.1021/acs.analchem.5c03744
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A CRISPR-Cas12a Fluorescent Aptasensor for Point-of-Care Drug Concentration Detection: A Synergistic Regulation by DNA Aptamer and RNA Blocker

Yiwei Liu, Zhoujie Liu, Chen-Zhi Zhang, Lixue Guo et al.
1 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
0.81
article

A CRISPR-Cas12a Fluorescent Aptasensor for Point-of-Care Drug Concentration Detection: A Synergistic Regulation by DNA Aptamer and RNA Blocker

Yiwei Liu, Zhoujie Liu, Chen-Zhi Zhang, Lixue Guo, Ye Yang, Yuewen Chen, Bing Wu, Chen Huang, Jin-Yuan Chen, Jiayi Li, Wei-Wei Lin
article en
1 citations

Abstract

The combination of CRISPR-Cas12a with aptamers can potentially improve the sensitivity, specificity, and speed of non-nucleic acid target detection. Nevertheless, current CRISPR-Cas12a aptasensors, solely dependent on aptamer affinity and overlooking the enzymatic regulation of CRISPR-Cas12a, may produce false-positive signals. We proposed a CRISPR-Cas12a aptasensor synergistically regulated by an aptamer and RNA, which incorporated aptamer-mediated drug recognition and CRISPR-powered signal amplification in a one-pot format. Herein, a regulatory RNA probe synergized with the conformational switching of a drug-induced aptamer, enabling precise regulation of Cas12a trans-cleavage activity via toehold-mediated strand displacement (TMSD). This dual regulatory mechanism transformed the aptamer-activated CRISPR-Cas12a sensing process into a TMSD-driven conditional reaction, avoiding false-positive signals and thus achieving better detection performance with a lower detection limit. With the vancomycin (VCM) aptamer as a model, the aptasensor can detect VCM within 30 min from 2% serum, 1% synovial fluid, and 1% cerebrospinal fluid, with a detection limit of 13.62, 7.56, and 6.75 nM, respectively. The proposed aptasensor was incorporated into a custom 3D-printed portable fluorometer and underwent clinical validation in 22 VCM serum samples, reporting no significant difference when compared with the enzyme-multiplied immunoassay technique, confirming the reliability for point-of-care quantification. It further received cross-validation with a quinine aptamer, suggesting universality [a linear range of 10-250 nM (<i>R</i><sup>2</sup> = 0.985) and a detection limit of 0.42 nM]. By integration of aptamer selectivity with CRISPR programmability, this work presents a novel robust biosensing paradigm for point-of-care drug concentration detection.

Analytical ChemistryVol. 97(44)
Fujian Medical University (CN), First Affiliated Hospital of Fujian Medical University (CN)
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.