A Triple-Input AND-Logic System Employing an APE1-Propelled Bipedal DNA Walker for Highly Sensitive Detection of Dual miRNAs

The escalating global cancer burden necessitates the development of precise tumor-specific microRNA (miRNA) detection strategies. However, the low-abundance, short-length, and high-sequence homology of miRNAs significantly hinder their accurate detection. Moreover, growing evidence of miRNA codysregulation in tumorigenesis underscores the diagnostic advantage of multiplexed analysis over single-marker approaches. Here, we present a novel bipedal DNA walker-based biosensor (BDWA) assembled on gold nanoparticles for the simultaneous detection of dual-miRNA targets. This system uniquely integrates dual-miRNA responsiveness with tumor-endogenous enzyme-driven signal amplification operating within a triple-input orthogonal AND-logic gate framework to enhance diagnostic specificity. Specifically, the concurrent presence of miR-21 and miR-155 displaces blocking strands to activate the walker, while the tumor-associated endonuclease APE1 serves as an intracellular trigger that propels the walker along engineered hairpin tracks (H1) on AuNPs. APE1-mediated cleavage of abasic (AP) sites results in the release and amplification of fluorescence signals initiated by the dual-targets. The bipedal architecture of the walker ensures a high processivity and efficient signal amplification. Critically, this design produces output signals only when all three inputs─miR-21, miR-155, and APE1─are present, thereby minimizing background interference and false positives. The BDWA system demonstrates high sensitivity and specificity for dual-miRNA detection in tumor cell lysates and intracellular imaging, offering a robust, tumor-activated, and programmable molecular platform for next-generation cancer diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-10-27
DOI
https://doi.org/10.1021/acssensors.5c02731
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Triple-Input AND-Logic System Employing an APE1-Propelled Bipedal DNA Walker for Highly Sensitive Detection of Dual miRNAs

Hong Wang, Haoping Zhang, Zhao–You Tang, Yingwei Zhang et al.
3 citations
ACS Sensors
Advanced biosensing and bioanalysis techniques
2.42
article

A Triple-Input AND-Logic System Employing an APE1-Propelled Bipedal DNA Walker for Highly Sensitive Detection of Dual miRNAs

Hong Wang, Haoping Zhang, Zhao–You Tang, Yingwei Zhang, Jingyu Tao, Min Pan, Xinyi Wang
article en
3 citations

Abstract

The escalating global cancer burden necessitates the development of precise tumor-specific microRNA (miRNA) detection strategies. However, the low-abundance, short-length, and high-sequence homology of miRNAs significantly hinder their accurate detection. Moreover, growing evidence of miRNA codysregulation in tumorigenesis underscores the diagnostic advantage of multiplexed analysis over single-marker approaches. Here, we present a novel bipedal DNA walker-based biosensor (BDWA) assembled on gold nanoparticles for the simultaneous detection of dual-miRNA targets. This system uniquely integrates dual-miRNA responsiveness with tumor-endogenous enzyme-driven signal amplification operating within a triple-input orthogonal AND-logic gate framework to enhance diagnostic specificity. Specifically, the concurrent presence of miR-21 and miR-155 displaces blocking strands to activate the walker, while the tumor-associated endonuclease APE1 serves as an intracellular trigger that propels the walker along engineered hairpin tracks (H1) on AuNPs. APE1-mediated cleavage of abasic (AP) sites results in the release and amplification of fluorescence signals initiated by the dual-targets. The bipedal architecture of the walker ensures a high processivity and efficient signal amplification. Critically, this design produces output signals only when all three inputs─miR-21, miR-155, and APE1─are present, thereby minimizing background interference and false positives. The BDWA system demonstrates high sensitivity and specificity for dual-miRNA detection in tumor cell lysates and intracellular imaging, offering a robust, tumor-activated, and programmable molecular platform for next-generation cancer diagnostics.

ACS SensorsVol. 10(11)
Division of Materials Science and Engineering (AU), State Key Laboratory of Chemical Engineering (CN), Beijing University of Chemical Technology (CN)
Openalex Percentile: Top 10%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.