Efficacy of a new detector automatic exposure control in portable anteroposterior chest radiography: a retrospective examination of radiation dose optimization and image quality

BackgroundAutomatic exposure control (AEC) devices are necessary to reduce the radiation dose and enhance image quality in radiography. However, AEC devices are not being used in portable X-ray systems due to technical issues.PurposeTo evaluate the radiation dose and image quality of a new AEC for a wireless portable X-ray system compared to the standard fixed radiation dose of manual controls in chest radiography.Material and MethodsThis retrospective analysis evaluated the performance of a portable X-ray system equipped with software-based AEC on anteroposterior chest radiographs. A quantitative evaluation comparing the manual and AEC groups was conducted to ascertain the exposure index (EI) and dose-area product (DAP). We performed observer-based analysis of image quality for lowest exposure and average exposure images in the manual and AEC groups.ResultsOverall, 2093 examinations were conducted in 467 patients. AEC yielded a statistically significant reduction in the DAP (AEC: 1.64 dGycm<sup>2</sup>; manual: 1.99 dGycm<sup>2</sup>) and EI (AEC: 266; manual: 393) compared to manual control (<i>P</i> <0.001). Evaluation of the average and low exposure images revealed that the DAP and EI were consistently lower in the AEC group (<i>P</i> <0.01). Observer-based analysis of the lowest exposure images revealed that AEC yielded a statistically significant higher score compared to manual control (12.5 manual, 13.4 AEC; <i>P</i> <0.001).ConclusionAEC within a wireless portable X-ray system improves subjective image quality while reducing radiation exposure, as substantiated by quantitative and qualitative metrics.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-10-27
DOI
https://doi.org/10.1177/02841851251387448
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of a new detector automatic exposure control in portable anteroposterior chest radiography: a retrospective examination of radiation dose optimization and image quality

Yoon Ki, Myung Jin Chung, D H Kim, Sang‐Uk Kim et al.
Acta Radiologica
Radiation Dose and Imaging
article

Efficacy of a new detector automatic exposure control in portable anteroposterior chest radiography: a retrospective examination of radiation dose optimization and image quality

Yoon Ki, Myung Jin Chung, D H Kim, Sang‐Uk Kim, Jung Han Woo, Dong Hun Lee
article en

Abstract

BackgroundAutomatic exposure control (AEC) devices are necessary to reduce the radiation dose and enhance image quality in radiography. However, AEC devices are not being used in portable X-ray systems due to technical issues.PurposeTo evaluate the radiation dose and image quality of a new AEC for a wireless portable X-ray system compared to the standard fixed radiation dose of manual controls in chest radiography.Material and MethodsThis retrospective analysis evaluated the performance of a portable X-ray system equipped with software-based AEC on anteroposterior chest radiographs. A quantitative evaluation comparing the manual and AEC groups was conducted to ascertain the exposure index (EI) and dose-area product (DAP). We performed observer-based analysis of image quality for lowest exposure and average exposure images in the manual and AEC groups.ResultsOverall, 2093 examinations were conducted in 467 patients. AEC yielded a statistically significant reduction in the DAP (AEC: 1.64 dGycm<sup>2</sup>; manual: 1.99 dGycm<sup>2</sup>) and EI (AEC: 266; manual: 393) compared to manual control (<i>P</i> <0.001). Evaluation of the average and low exposure images revealed that the DAP and EI were consistently lower in the AEC group (<i>P</i> <0.01). Observer-based analysis of the lowest exposure images revealed that AEC yielded a statistically significant higher score compared to manual control (12.5 manual, 13.4 AEC; <i>P</i> <0.001).ConclusionAEC within a wireless portable X-ray system improves subjective image quality while reducing radiation exposure, as substantiated by quantitative and qualitative metrics.

Acta RadiologicaVol. 67(1)
Samsung (South Korea) (KR), Samsung Medical Center (KR), Chung-Ang University Hospital (KR), Sungkyunkwan University (KR)
Openalex Percentile: Top 54%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.