MED-EL hearing solution registry: An examination of the strengths and limitations of a cochlear implant registry

There is a significant gap in routine clinical data concerning cochlear implant (CI) users, particularly regarding real-world outcomes. To address this, the present study focuses on the MED-EL Hearing Solution (MEHS) multicenter registry, which covers 5 clinics in Germany. Participants were users of a SONNET 2 or SONNET 2 EAS audio processor. Anonymized data that were routinely collected were extracted and analyzed by a third-party organization. Speech test outcomes (monosyllables and numbers), hours of daily use, self-perceived level of auditory benefit, and safety were assessed. Outcomes from 361 SONNET 2 (or SONNET 2 EAS) users, including 57 bilateral users, were extracted and analyzed. Speech test outcomes increased significantly from pre-operatively to 1 year of CI use in monosyllables (median 10.0% to 65.0%) and numbers (median 77.8% to 100.0%) (both p < 0.001). The majority (79%) of people used their device for at least 9 hours a day. The level of self-perceived auditory benefit was "moderate". Safety was assessed as per participant self-report: 17 minor clinical events were reported, none were new or unresolved. The data obtained from the MEHS registry offers valuable real-life evidence from routine clinical evaluations, which can support clinicians in developing more informed guidelines and treatment plans. The SONNET 2 (EAS) is effective and safe to use. Registries have the potential to provide a wealth of data that can be used to improve hearing health care. However, the success of registries depends on consistent participation and adherence to standardized protocols by clinical centers. Variability in clinical practices, demographic factors, and reporting standards across centers poses significant challenges to achieving homogeneous and usable data.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-27
DOI
https://doi.org/10.1371/journal.pone.0335345
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MED-EL hearing solution registry: An examination of the strengths and limitations of a cochlear implant registry

Daniel Polterauer, Karin A. Koinig, Vera Lohnherr, Andreas Radeloff et al.
PLoS ONE
Hearing Loss and Rehabilitation
article

MED-EL hearing solution registry: An examination of the strengths and limitations of a cochlear implant registry

Daniel Polterauer, Karin A. Koinig, Vera Lohnherr, Andreas Radeloff, Ilona Anderson, Tobias Weißgerber, Uwe Baumann, Stefan Dazert, Christiane Völter, Joachim Müller, Magdalena Breu, Jasmine Rinnofner
article en

Abstract

There is a significant gap in routine clinical data concerning cochlear implant (CI) users, particularly regarding real-world outcomes. To address this, the present study focuses on the MED-EL Hearing Solution (MEHS) multicenter registry, which covers 5 clinics in Germany. Participants were users of a SONNET 2 or SONNET 2 EAS audio processor. Anonymized data that were routinely collected were extracted and analyzed by a third-party organization. Speech test outcomes (monosyllables and numbers), hours of daily use, self-perceived level of auditory benefit, and safety were assessed. Outcomes from 361 SONNET 2 (or SONNET 2 EAS) users, including 57 bilateral users, were extracted and analyzed. Speech test outcomes increased significantly from pre-operatively to 1 year of CI use in monosyllables (median 10.0% to 65.0%) and numbers (median 77.8% to 100.0%) (both p < 0.001). The majority (79%) of people used their device for at least 9 hours a day. The level of self-perceived auditory benefit was "moderate". Safety was assessed as per participant self-report: 17 minor clinical events were reported, none were new or unresolved. The data obtained from the MEHS registry offers valuable real-life evidence from routine clinical evaluations, which can support clinicians in developing more informed guidelines and treatment plans. The SONNET 2 (EAS) is effective and safe to use. Registries have the potential to provide a wealth of data that can be used to improve hearing health care. However, the success of registries depends on consistent participation and adherence to standardized protocols by clinical centers. Variability in clinical practices, demographic factors, and reporting standards across centers poses significant challenges to achieving homogeneous and usable data.

PLoS ONEVol. 20(10)
Goethe University Frankfurt (DE), Carl von Ossietzky Universität Oldenburg (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Augenklinik Heidelberg (DE), St. Elisabeth-Hospital Bochum (DE), Hautklinik Heidelberg (DE), University Hospital Frankfurt (DE), MED-EL (Austria) (AT), Ludwig-Maximilians-Universität München (DE)
MED-EL Medical Electronics
Openalex Percentile: Top 69%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.