Ventilatory inefficiency limits 6-min walked distance in systemic sclerosis-associated interstitial lung disease

Systemic sclerosis-associated interstitial lung disease (SSc-ILD) impacts cardiopulmonary systems and exercise capacity serves as a marker of disease severity. While the six-minute walking test (6MWT) is widely used to assess physical performance, its limitations to assess the cardiopulmonary function remain unresolved in SSc-ILD patients. This study aimed to investigate cardiorespiratory adaptations during the 6MWT, hypothesizing that ventilatory inefficiency is related to exercise capacity in SSc-ILD patients. We recruited 23 female SSc-ILD patients and 13 age- and sex-matched healthy controls (HC). Inclusion criteria included SSc diagnosis (limited or diffuse cutaneous subset) with mild-to-moderate associated ILD. Participants performed 6MWT with combined cardiopulmonary exercise testing (CPET) assessment using a wearable metabolic system to measure ventilatory and gas exchange parameters, including minute ventilation (VE), respiratory frequency (Rf), tidal volume (Vt), and ventilatory equivalent for CO<sub>2</sub> (VE/VCO<sub>2</sub>). SSc-ILD patients exhibited increased Rf and VE during the initial minutes of exercise and during recovery compared to HC. Despite similar walking distances, SSc-ILD demonstrated higher VE/VCO<sub>2</sub> during the 6MWT. VE/VCO<sub>2</sub> was negatively correlated with 6MWT distance (6MWD) in SSc-ILD but not in HC. Patients walking more than 474 m (median) presented higher VE/VCO<sub>2</sub> than HC with same 6MWD. SSc-ILD patients showed a general impaired ventilatory efficiency during 6MWT. The main result suggests that exercise capacity is not only linked to global cardiovascular adaptation but also to ventilatory performance. These findings underscore the importance of incorporating CPET metrics to cardiorespiratory assessments to improve clinical understanding and assessment of SSc-ILD.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-27
DOI
https://doi.org/10.1038/s41598-025-17279-5
Primary Topic
Systemic Sclerosis and Related Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilatory inefficiency limits 6-min walked distance in systemic sclerosis-associated interstitial lung disease

Chiara Bellocchi, Nicola Montano, Marco Vicenzi, Gabriel Dias Rodrigues et al.
Scientific Reports
Systemic Sclerosis and Related Diseases
article

Ventilatory inefficiency limits 6-min walked distance in systemic sclerosis-associated interstitial lung disease

Chiara Bellocchi, Nicola Montano, Marco Vicenzi, Gabriel Dias Rodrigues, Gaël Deboeck, Stefano Carugo, Lorenzo Beretta, Eleonora Tobaldini
article en

Abstract

Systemic sclerosis-associated interstitial lung disease (SSc-ILD) impacts cardiopulmonary systems and exercise capacity serves as a marker of disease severity. While the six-minute walking test (6MWT) is widely used to assess physical performance, its limitations to assess the cardiopulmonary function remain unresolved in SSc-ILD patients. This study aimed to investigate cardiorespiratory adaptations during the 6MWT, hypothesizing that ventilatory inefficiency is related to exercise capacity in SSc-ILD patients. We recruited 23 female SSc-ILD patients and 13 age- and sex-matched healthy controls (HC). Inclusion criteria included SSc diagnosis (limited or diffuse cutaneous subset) with mild-to-moderate associated ILD. Participants performed 6MWT with combined cardiopulmonary exercise testing (CPET) assessment using a wearable metabolic system to measure ventilatory and gas exchange parameters, including minute ventilation (VE), respiratory frequency (Rf), tidal volume (Vt), and ventilatory equivalent for CO<sub>2</sub> (VE/VCO<sub>2</sub>). SSc-ILD patients exhibited increased Rf and VE during the initial minutes of exercise and during recovery compared to HC. Despite similar walking distances, SSc-ILD demonstrated higher VE/VCO<sub>2</sub> during the 6MWT. VE/VCO<sub>2</sub> was negatively correlated with 6MWT distance (6MWD) in SSc-ILD but not in HC. Patients walking more than 474 m (median) presented higher VE/VCO<sub>2</sub> than HC with same 6MWD. SSc-ILD patients showed a general impaired ventilatory efficiency during 6MWT. The main result suggests that exercise capacity is not only linked to global cardiovascular adaptation but also to ventilatory performance. These findings underscore the importance of incorporating CPET metrics to cardiorespiratory assessments to improve clinical understanding and assessment of SSc-ILD.

Scientific ReportsVol. 15(1)
Université Libre de Bruxelles (BE), University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Ospedale Maggiore (IT)
Openalex Percentile: Top 57%
Systemic Sclerosis and Related Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.