Rapid detection of herpes simplex virus types 1 and 2 using a G-quadruplex aptamer-based biosensor

Herpes simplex virus types 1 and 2 (HSV-1 and HSV-2), which cause oral and genital herpes in humans, are prevalent worldwide. ELISA, real-time PCR, and cytological assays are conventional methods for detecting these viruses, but they are expensive and time-consuming. The main purpose of this study was to design a specific G-quadruplex aptamer for the simple and rapid detection of HSV-1 and HSV-2. In this study, a specific aptamer was designed using bioinformatics tools for binding to the glycoprotein gD in HSV-1 and HSV-2. After evaluating the binding of the aptamer to gD, based on the stability scores of the secondary and tertiary structures and molecular docking, the aptamer AptNR88 was selected, and its binding to the target protein was confirmed experimentally using a colorimetric system with gold nanoparticles. Gold nanoparticles with an average size of 30 nm were synthesized, and the AptNR88 was coated on them through hydrogen bonds and electrostatic interactions. The concentration of AptNR88 was subsequently optimized for resistance against salt-induced aggregation. The color changes of gold nanoparticles from red to purple due to salt aggregation were observed only in the presence of the AptNR88-virus complex after 15 min. These results confirmed the specific binding of AptNR88 to the gD of HSV-1 and HSV-2. The limit of detection (LOD) for AptNR88 was approximately 11.7 copies/ml for HSV-1 and 15.7 copies/ml for HSV-2. These results indicate that the designed aptamer for detecting these two viruses is sufficiently sensitive and specific.

Authors

Institutions

Publication Details

Journal
Virology Journal
Published
2025-10-27
DOI
https://doi.org/10.1186/s12985-025-02949-7
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid detection of herpes simplex virus types 1 and 2 using a G-quadruplex aptamer-based biosensor

Salar Nouri, Mandana Behbahani, Hassan Mohabatkar, Soheil Shajari
1 citations
Virology Journal
Advanced biosensing and bioanalysis techniques
0.81
article

Rapid detection of herpes simplex virus types 1 and 2 using a G-quadruplex aptamer-based biosensor

Salar Nouri, Mandana Behbahani, Hassan Mohabatkar, Soheil Shajari
article en
1 citations

Abstract

Herpes simplex virus types 1 and 2 (HSV-1 and HSV-2), which cause oral and genital herpes in humans, are prevalent worldwide. ELISA, real-time PCR, and cytological assays are conventional methods for detecting these viruses, but they are expensive and time-consuming. The main purpose of this study was to design a specific G-quadruplex aptamer for the simple and rapid detection of HSV-1 and HSV-2. In this study, a specific aptamer was designed using bioinformatics tools for binding to the glycoprotein gD in HSV-1 and HSV-2. After evaluating the binding of the aptamer to gD, based on the stability scores of the secondary and tertiary structures and molecular docking, the aptamer AptNR88 was selected, and its binding to the target protein was confirmed experimentally using a colorimetric system with gold nanoparticles. Gold nanoparticles with an average size of 30 nm were synthesized, and the AptNR88 was coated on them through hydrogen bonds and electrostatic interactions. The concentration of AptNR88 was subsequently optimized for resistance against salt-induced aggregation. The color changes of gold nanoparticles from red to purple due to salt aggregation were observed only in the presence of the AptNR88-virus complex after 15 min. These results confirmed the specific binding of AptNR88 to the gD of HSV-1 and HSV-2. The limit of detection (LOD) for AptNR88 was approximately 11.7 copies/ml for HSV-1 and 15.7 copies/ml for HSV-2. These results indicate that the designed aptamer for detecting these two viruses is sufficiently sensitive and specific.

Virology JournalVol. 22(1)
Isfahan University of Technology (IR), University of Isfahan (IR)
University of Isfahan
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid detection of herpes simplex virus types 1 and 2 using a G-quadruplex aptamer-based biosensor — Salar Nouri, Mandana Behbahani, et al. · Virology Journal (2025) | TGRS Research Map | TGRS