Experimental study of nanosecond surface dielectric barrier discharge for plasma-assisted ammonia combustion: Effects of pulse number and pulse interval

Plasma-Assisted Ammonia Combustion (PAAC) addresses several challenges of using Ammonia (NH 3 ) as a carbon-free fuel. Nanosecond Surface Dielectric Barrier Discharge (nSDBD) is an effective strategy with improved ignition and combustion efficiencies for PAAC. The effectiveness of nSDBD depends on both discharge device and parameters. However, there is a lack of experimental investigations into discharge parameters of PAAC ignited by nSDBD. This research experimentally examined two significant discharge parameters: pulse number (PN) and pulse interval (PI). Stoichiometric NH 3 /air mixture was placed into a Constant Volume Chamber (CVC) at the initial pressure of 1 bar and the initial temperature of 90 ∘ C. Nanosecond pulses at the voltage of 15 kV were generated by a self-designed power source and applied to an nSDBD device. The results show that increasing PN enhances ignition success, flame kernel growth, and combustion performance, up to an optimal point at PN = 180. Shorter PI improves the supplied energy to the nSDBD per pulse, accelerating flame kernel expansion and ignition. However, excessively short PI (e.g., 50 μ s ) leads to gas disturbances and potential radical quenching, while intermediate PI (e.g., 80 μ s ) introduces anisotropic spatial distribution and poor combustion repeatability. The optimal discharge setting was found to be PN = 180 and PI = 60 μ s at the initial pressure of 1.0 bar and the initial temperature of 90 ∘ C , achieving the fastest combustion and highest heat release. This study fills the current experimental gap and provides practical guidelines for the design of efficient PAAC systems. • Nanosecond-scale high-frequency nSDBD was applied in NH 3 /air mixtures for ignition. • Effects of pulse number and pulse interval of nSDBD discharge on NH 3 ignition. • Pulse number of 180 and pulse interval of 60 μ s achieved optimal combustion at the initial pressure of 1.0 bar and the initial temperature of 90 ∘ C. • Excessive pulse numbers or overly short pulse intervals lead to deteriorated combustion performance.

Authors

Institutions

Publication Details

Journal
Fuel
Published
2025-10-27
DOI
https://doi.org/10.1016/j.fuel.2025.137271
Citations
2
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of nanosecond surface dielectric barrier discharge for plasma-assisted ammonia combustion: Effects of pulse number and pulse interval

Yong Cheng, Michael J. Pekris, Guohong Tian, Yong Xiong et al.
2 citations
Fuel
Plasma Applications and Diagnostics
2.72
article

Experimental study of nanosecond surface dielectric barrier discharge for plasma-assisted ammonia combustion: Effects of pulse number and pulse interval

Yong Cheng, Michael J. Pekris, Guohong Tian, Yong Xiong, Qingwu Zhao, Deyan Kong
article en
2 citations

Abstract

Plasma-Assisted Ammonia Combustion (PAAC) addresses several challenges of using Ammonia (NH 3 ) as a carbon-free fuel. Nanosecond Surface Dielectric Barrier Discharge (nSDBD) is an effective strategy with improved ignition and combustion efficiencies for PAAC. The effectiveness of nSDBD depends on both discharge device and parameters. However, there is a lack of experimental investigations into discharge parameters of PAAC ignited by nSDBD. This research experimentally examined two significant discharge parameters: pulse number (PN) and pulse interval (PI). Stoichiometric NH 3 /air mixture was placed into a Constant Volume Chamber (CVC) at the initial pressure of 1 bar and the initial temperature of 90 ∘ C. Nanosecond pulses at the voltage of 15 kV were generated by a self-designed power source and applied to an nSDBD device. The results show that increasing PN enhances ignition success, flame kernel growth, and combustion performance, up to an optimal point at PN = 180. Shorter PI improves the supplied energy to the nSDBD per pulse, accelerating flame kernel expansion and ignition. However, excessively short PI (e.g., 50 μ s ) leads to gas disturbances and potential radical quenching, while intermediate PI (e.g., 80 μ s ) introduces anisotropic spatial distribution and poor combustion repeatability. The optimal discharge setting was found to be PN = 180 and PI = 60 μ s at the initial pressure of 1.0 bar and the initial temperature of 90 ∘ C , achieving the fastest combustion and highest heat release. This study fills the current experimental gap and provides practical guidelines for the design of efficient PAAC systems. • Nanosecond-scale high-frequency nSDBD was applied in NH 3 /air mixtures for ignition. • Effects of pulse number and pulse interval of nSDBD discharge on NH 3 ignition. • Pulse number of 180 and pulse interval of 60 μ s achieved optimal combustion at the initial pressure of 1.0 bar and the initial temperature of 90 ∘ C. • Excessive pulse numbers or overly short pulse intervals lead to deteriorated combustion performance.

FuelVol. 407
University of Surrey (GB), University of Jinan (CN)
Openalex Percentile: Top 8%
Plasma Applications and Diagnostics
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.