Postoperative data leakage in AI-based IOL power prediction formulas: a hidden source of bias

This study addresses a critical bias in non-optical formulas purely based on AI models and designed to predict the implanted power using the postoperative spherical equivalent (SE) as an input. Two predictive models were developed using the XGBoost algorithm on a training set of 4588 eyes implanted with Finevision IOLs. One model (AI Pred. SE) was trained to predict the postoperative SE from the implanted power and biometric data, while the second model (AI Pred. Power) was designed to predict the implanted IOL power using the achieved SE and biometric data. Both models were evaluated on an independent testing set using standard performance metrics. The logic of the optical behavior was then assessed for each model, by varying the relevant input (SE for AI Pred. Power, Power for AI Pred. SE) across a broad range of values. On standard evaluation, the AI Pred. Power model showed the lowest prediction error (Friedman test p < 0.0001), outperforming conventional formula. However, despite its accuracy in predicting the implanted IOL power, this architecture returned a predicted power that was largely invariant and non-physiologically responsive to changes in the target refraction regardless of the target refraction entered as an input, for a given eye. This finding underscores the importance of excluding real postoperative refractive outcomes from any evaluation processes or formula design. We hypothesize that this common evaluation paradigm for pure-AI formulas creates a fundamental and undetectable bias, producing models that are optimized for retrospective prediction but are incapable of prospective clinical application.

Authors

Institutions

Publication Details

Journal
Experimental Eye Research
Published
2025-10-27
DOI
https://doi.org/10.1016/j.exer.2025.110700
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Postoperative data leakage in AI-based IOL power prediction formulas: a hidden source of bias

Damien Gatinel, Nicole Mechleb, Guillaume Debellemanière, B Barreiro Luis et al.
Experimental Eye Research
Retinal Imaging and Analysis
article

Postoperative data leakage in AI-based IOL power prediction formulas: a hidden source of bias

Damien Gatinel, Nicole Mechleb, Guillaume Debellemanière, B Barreiro Luis, Alain Saad, Antonio H. Lara, G. Mathieu, Wallerstein Avi, Dai Huan Yu Lily, Tabunar Lauren
article en

Abstract

This study addresses a critical bias in non-optical formulas purely based on AI models and designed to predict the implanted power using the postoperative spherical equivalent (SE) as an input. Two predictive models were developed using the XGBoost algorithm on a training set of 4588 eyes implanted with Finevision IOLs. One model (AI Pred. SE) was trained to predict the postoperative SE from the implanted power and biometric data, while the second model (AI Pred. Power) was designed to predict the implanted IOL power using the achieved SE and biometric data. Both models were evaluated on an independent testing set using standard performance metrics. The logic of the optical behavior was then assessed for each model, by varying the relevant input (SE for AI Pred. Power, Power for AI Pred. SE) across a broad range of values. On standard evaluation, the AI Pred. Power model showed the lowest prediction error (Friedman test p < 0.0001), outperforming conventional formula. However, despite its accuracy in predicting the implanted IOL power, this architecture returned a predicted power that was largely invariant and non-physiologically responsive to changes in the target refraction regardless of the target refraction entered as an input, for a given eye. This finding underscores the importance of excluding real postoperative refractive outcomes from any evaluation processes or formula design. We hypothesize that this common evaluation paradigm for pure-AI formulas creates a fundamental and undetectable bias, producing models that are optimized for retrospective prediction but are incapable of prospective clinical application.

Experimental Eye ResearchVol. 262
University of Toronto (CA), Fondation de Rothschild (FR), McGill University (CA), Université de Montréal (CA)
Openalex Percentile: Top 55%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.