A variable thermal transmittance adaptive wall: comparison between CFD simulations and experimental tests

• A wall with variable thermophysical properties is proposed; • The wall thermal transmittance may be reduced up to ten times in a few minutes; • CFD simulations assess the thermal behaviour in different conditions; • Hot box experimental tests validated the performance of the innovative wall. Building energy consumption plays a major role in global greenhouse gas emissions. Traditional building envelopes struggle to adapt to fluctuating environmental conditions. This study investigates an innovative solution: the variable thermal transmittance wall: an adaptive building envelope capable of dynamically modifying its insulation level to optimize energy performance. The system incorporates embedded fluid-filled coils on both inner and outer wall surfaces. By controlling the fluid circulation, the wall can switch between insulating and conductive states, enhancing thermal comfort and reducing reliance on HVAC systems. A comprehensive approach combining Computational Fluid Dynamics (CFD) simulations and experimental testing was used to evaluate the wall performance. CFD analyses provided detailed insights into temperature distributions and thermal transmittance, while experimental tests using a hot box apparatus validated the numerical results. Materials used in the wall were also tested with a guarded hot plate to ensure accurate input data. Results show that the thermal transmittance can be adjusted by over a factor of ten (from 0.32 W/m 2 K up to 3.22 W/m 2 K), allowing the wall to function adaptively across different seasonal and diurnal conditions. The close agreement between CFD and experimental data, with differences moving from 3 % to 13 %, confirms the potential of this technology to significantly reduce energy consumption and improve building sustainability.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-10-27
DOI
https://doi.org/10.1016/j.enbuild.2025.116629
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A variable thermal transmittance adaptive wall: comparison between CFD simulations and experimental tests

Agnieszka Lechowska, Giorgio Baldinelli, Jacek Schnotale, Francesco Paolo Bianchi
1 citations
Energy and Buildings
Building Energy and Comfort Optimization
1.01
article

A variable thermal transmittance adaptive wall: comparison between CFD simulations and experimental tests

Agnieszka Lechowska, Giorgio Baldinelli, Jacek Schnotale, Francesco Paolo Bianchi
article en
1 citations

Abstract

• A wall with variable thermophysical properties is proposed; • The wall thermal transmittance may be reduced up to ten times in a few minutes; • CFD simulations assess the thermal behaviour in different conditions; • Hot box experimental tests validated the performance of the innovative wall. Building energy consumption plays a major role in global greenhouse gas emissions. Traditional building envelopes struggle to adapt to fluctuating environmental conditions. This study investigates an innovative solution: the variable thermal transmittance wall: an adaptive building envelope capable of dynamically modifying its insulation level to optimize energy performance. The system incorporates embedded fluid-filled coils on both inner and outer wall surfaces. By controlling the fluid circulation, the wall can switch between insulating and conductive states, enhancing thermal comfort and reducing reliance on HVAC systems. A comprehensive approach combining Computational Fluid Dynamics (CFD) simulations and experimental testing was used to evaluate the wall performance. CFD analyses provided detailed insights into temperature distributions and thermal transmittance, while experimental tests using a hot box apparatus validated the numerical results. Materials used in the wall were also tested with a guarded hot plate to ensure accurate input data. Results show that the thermal transmittance can be adjusted by over a factor of ten (from 0.32 W/m 2 K up to 3.22 W/m 2 K), allowing the wall to function adaptively across different seasonal and diurnal conditions. The close agreement between CFD and experimental data, with differences moving from 3 % to 13 %, confirms the potential of this technology to significantly reduce energy consumption and improve building sustainability.

Energy and BuildingsVol. 350
Cracow University of Technology (PL), University of Perugia (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Perugia (IT)
Openalex Percentile: Top 19%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.