Successful Endovascular Repair of a Narrow-Ruptured Aorta With an Iliac Branch Device: Case Report and Literature Review

A 47-year-old man with a history of drug addiction sustained an aortic rupture with a clinical status of shock and sepsis. An open repair was not possible because of his unstable hemodynamics, the suspicion of an infected aorta and a very hostile abdomen. However, the endovascular approach would have been very challenging due to a very narrow infrarenal aorta. A Gore iliac branch endoprosthesis was successfully deployed as a bifurcated aortic stent graft and the aortic rupture was completely excluded. The patient was discharged after 20 days with long-term antibiotic and antifungal therapy. No signs of migration or limb occlusion at 6 months computed tomography scan were detected. This off-label use of an iliac branch device (IBD) with a precannulated gate appears to be a good solution in emergency repair of a very narrow ruptured aorta.Clinical ImpactWe report the case of an iliac branch endoprosthesis used as a bifurcated aortic stent graft in a very narrow ruptured infrarenal aorta. The report describes a new approach that can be useful in emergencies to deal with aortic ruptures when a narrowed lumen forbids the use of a standard endograft.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2025-10-26
DOI
https://doi.org/10.1177/15266028251386288
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Successful Endovascular Repair of a Narrow-Ruptured Aorta With an Iliac Branch Device: Case Report and Literature Review

Isabella Patruno, Claudio Desantis, Massimo Ruggiero, Pietro Boggia et al.
Journal of Endovascular Therapy
Aortic aneurysm repair treatments
article

Successful Endovascular Repair of a Narrow-Ruptured Aorta With an Iliac Branch Device: Case Report and Literature Review

Isabella Patruno, Claudio Desantis, Massimo Ruggiero, Pietro Boggia, A. Coste
article en

Abstract

A 47-year-old man with a history of drug addiction sustained an aortic rupture with a clinical status of shock and sepsis. An open repair was not possible because of his unstable hemodynamics, the suspicion of an infected aorta and a very hostile abdomen. However, the endovascular approach would have been very challenging due to a very narrow infrarenal aorta. A Gore iliac branch endoprosthesis was successfully deployed as a bifurcated aortic stent graft and the aortic rupture was completely excluded. The patient was discharged after 20 days with long-term antibiotic and antifungal therapy. No signs of migration or limb occlusion at 6 months computed tomography scan were detected. This off-label use of an iliac branch device (IBD) with a precannulated gate appears to be a good solution in emergency repair of a very narrow ruptured aorta.Clinical ImpactWe report the case of an iliac branch endoprosthesis used as a bifurcated aortic stent graft in a very narrow ruptured infrarenal aorta. The report describes a new approach that can be useful in emergencies to deal with aortic ruptures when a narrowed lumen forbids the use of a standard endograft.

Journal of Endovascular Therapy
Ospedale A. Perrino (IT)
Openalex Percentile: Top 55%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.