Labor Induction with Synthetic Oxytocin and Infantile Colic: A Case–Control Study

<i>Background and Objectives</i>: Infantile colic affects 15-40% of infants ≤ 5 months, burdening families and health systems. While the effects of intrapartum oxytocin on neonatal outcomes have been widely investigated, its potential link with infantile colic remains poorly understood. We evaluated whether synthetic oxytocin is associated with infantile colic during the first five months of life and explored neonatal head circumference, feeding type and epidural anesthesia as additional factors. <i>Materials and Methods</i>: Prospective 1:1 matched case-control study in three Spanish pediatric outpatient clinics. Parents of 76 term infants aged 0-5 months (38 cases, 38 controls) completed face-to-face structured interviews documenting synthetic oxytocin and epidural use, infant anthropometry and feeding pattern. Infantile colic was diagnosed by Rome IV criteria. Associations were estimated with conditional logistic regression, producing adjusted odds ratios and 95% confidence intervals. <i>Results</i>: Synthetic oxytocin was used in 57.9% of deliveries and epidural anesthesia in 81.6%. Synthetic oxytocin showed no association with infantile colic (aOR 1.24; 95% CI 0.50-3.09). Epidural strongly predicted synthetic oxytocin exposure (aOR 4.55; 95% CI 1.28-16.20) but had no independent link to infantile colic. Infants with colic had a smaller mean head circumference at birth, although this difference did not remain significant after adjusting for gestational age, likely reflecting limited sample size. Synthetic oxytocin was not associated with breastfeeding status. <i>Conclusions</i>: In this cohort, intrapartum synthetic oxytocin was not related to infantile colic or to feeding difficulties. Smaller head circumference among colic cases may warrant further investigation as a potential risk marker. The high co-use of synthetic oxytocin and epidural underscores the need for larger longitudinal studies to clarify their peripartum-neonatal interactions.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-10-24
DOI
https://doi.org/10.3390/medicina61111908
Primary Topic
Infant Health and Development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Labor Induction with Synthetic Oxytocin and Infantile Colic: A Case–Control Study

Arrate Pinto‐Carral, Raquel Leirós‐Rodríguez, Óscar Rodríguez‐Nogueira, María José Álvarez Álvarez et al.
Medicina
Infant Health and Development
article

Labor Induction with Synthetic Oxytocin and Infantile Colic: A Case–Control Study

Arrate Pinto‐Carral, Raquel Leirós‐Rodríguez, Óscar Rodríguez‐Nogueira, María José Álvarez Álvarez, Cristina Suárez-Fraga
article en

Abstract

<i>Background and Objectives</i>: Infantile colic affects 15-40% of infants ≤ 5 months, burdening families and health systems. While the effects of intrapartum oxytocin on neonatal outcomes have been widely investigated, its potential link with infantile colic remains poorly understood. We evaluated whether synthetic oxytocin is associated with infantile colic during the first five months of life and explored neonatal head circumference, feeding type and epidural anesthesia as additional factors. <i>Materials and Methods</i>: Prospective 1:1 matched case-control study in three Spanish pediatric outpatient clinics. Parents of 76 term infants aged 0-5 months (38 cases, 38 controls) completed face-to-face structured interviews documenting synthetic oxytocin and epidural use, infant anthropometry and feeding pattern. Infantile colic was diagnosed by Rome IV criteria. Associations were estimated with conditional logistic regression, producing adjusted odds ratios and 95% confidence intervals. <i>Results</i>: Synthetic oxytocin was used in 57.9% of deliveries and epidural anesthesia in 81.6%. Synthetic oxytocin showed no association with infantile colic (aOR 1.24; 95% CI 0.50-3.09). Epidural strongly predicted synthetic oxytocin exposure (aOR 4.55; 95% CI 1.28-16.20) but had no independent link to infantile colic. Infants with colic had a smaller mean head circumference at birth, although this difference did not remain significant after adjusting for gestational age, likely reflecting limited sample size. Synthetic oxytocin was not associated with breastfeeding status. <i>Conclusions</i>: In this cohort, intrapartum synthetic oxytocin was not related to infantile colic or to feeding difficulties. Smaller head circumference among colic cases may warrant further investigation as a potential risk marker. The high co-use of synthetic oxytocin and epidural underscores the need for larger longitudinal studies to clarify their peripartum-neonatal interactions.

MedicinaVol. 61(11)
Universidad de León (ES)
Universidad de León
Openalex Percentile: Top 50%
Infant Health and Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.