Effects of Ionizer Installation Conditions on Electrostatic Control Performance during Semiconductor Fabrication

Electrostatic discharge and particle contamination caused by static electricity contribute to yield loss during semiconductor manufacturing. Using insulating materials in process equipment causes static charge accumulation. Even small amounts of static charge can severely damage metal lines, gate oxides, or insulating layers. Although corona ionizers are widely adopted to control such issues, their performance is highly sensitive to installation conditions, including the position, angle, distance, and airflow. Improper conditions cause ion imbalance, fuzzball particle formation, and metal spattering, potentially leading to wafer defects that reduce the overall yield. Here, the correlation between fuzzball particles and wafer defects is verified using scanning electron microscopy and defect mapping. Root causes are identified and optimization strategies are suggested by evaluating ionizer installation angles and offsets within equipment front end modules and quantitatively measuring charge and discharge performance. The results provide foundational data for standardizing ionizer installation and improving process yields .

Authors

Publication Details

Journal
Journal of The Korean Society of Manufacturing Technology Engineers
Published
2025-10-15
DOI
https://doi.org/10.7735/ksmte.2025.34.5.315
Primary Topic
Thin-Film Transistor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Ionizer Installation Conditions on Electrostatic Control Performance during Semiconductor Fabrication

Taesun Hong, M.J. Lee, Tae-Hwan Kim
Journal of The Korean Society of Manufacturing Technology Engineers
Thin-Film Transistor Technologies
article

Effects of Ionizer Installation Conditions on Electrostatic Control Performance during Semiconductor Fabrication

Taesun Hong, M.J. Lee, Tae-Hwan Kim
article en

Abstract

Electrostatic discharge and particle contamination caused by static electricity contribute to yield loss during semiconductor manufacturing. Using insulating materials in process equipment causes static charge accumulation. Even small amounts of static charge can severely damage metal lines, gate oxides, or insulating layers. Although corona ionizers are widely adopted to control such issues, their performance is highly sensitive to installation conditions, including the position, angle, distance, and airflow. Improper conditions cause ion imbalance, fuzzball particle formation, and metal spattering, potentially leading to wafer defects that reduce the overall yield. Here, the correlation between fuzzball particles and wafer defects is verified using scanning electron microscopy and defect mapping. Root causes are identified and optimization strategies are suggested by evaluating ionizer installation angles and offsets within equipment front end modules and quantitatively measuring charge and discharge performance. The results provide foundational data for standardizing ionizer installation and improving process yields .

Journal of The Korean Society of Manufacturing Technology EngineersVol. 34(5)
Openalex Percentile: Top 69%
Thin-Film Transistor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Ionizer Installation Conditions on Electrostatic Control Performance during Semiconductor Fabrication — Taesun Hong, M.J. Lee, et al. · Journal of The Korean Society of Manufacturing Technology Engineers (2025) | TGRS Research Map | TGRS