Stretched Radial Trajectory Design for Efficient MRI with Enhanced K-Space Coverage and Image Resolution

We present a stretched radial trajectory design that enhances image resolution in MRI by expanding k-space coverage without increasing readout duration or scan time. The method dynamically modulates gradient amplitudes as a function of projection angle, achieving square k-space coverage in 2D and cubic coverage in 3D imaging. Validation was conducted using phantom and in vivo experiments on GE and Siemens scanners at 0.55 T and 3 T. Point spread function analysis and reconstructed images demonstrated improved sharpness and clearer visualization of fine structures, including small phantom details and brain vasculature. The approach also increased T<sub>1</sub> and T<sub>2</sub> mapping accuracy in MRF acquisitions. The proposed strategy requires no additional scan time or gradient hardware capability, making it well-suited for MRI systems with moderate performance. It offers a simple and generalizable means to improve spatial resolution in both structural and quantitative imaging applications.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-10-24
DOI
https://doi.org/10.3390/bioengineering12111152
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stretched Radial Trajectory Design for Efficient MRI with Enhanced K-Space Coverage and Image Resolution

Yanjun Qian, Zhitao Li, Congyu Liao, Liang Gong et al.
Bioengineering
Advanced MRI Techniques and Applications
article

Stretched Radial Trajectory Design for Efficient MRI with Enhanced K-Space Coverage and Image Resolution

Yanjun Qian, Zhitao Li, Congyu Liao, Liang Gong, Yang Yang, Xiaozhi Cao, Kawin Setsompop, Qinghua Li, Zihan Zhou
article en

Abstract

We present a stretched radial trajectory design that enhances image resolution in MRI by expanding k-space coverage without increasing readout duration or scan time. The method dynamically modulates gradient amplitudes as a function of projection angle, achieving square k-space coverage in 2D and cubic coverage in 3D imaging. Validation was conducted using phantom and in vivo experiments on GE and Siemens scanners at 0.55 T and 3 T. Point spread function analysis and reconstructed images demonstrated improved sharpness and clearer visualization of fine structures, including small phantom details and brain vasculature. The approach also increased T<sub>1</sub> and T<sub>2</sub> mapping accuracy in MRF acquisitions. The proposed strategy requires no additional scan time or gradient hardware capability, making it well-suited for MRI systems with moderate performance. It offers a simple and generalizable means to improve spatial resolution in both structural and quantitative imaging applications.

BioengineeringVol. 12(11)
Northwestern University (US), University of California, San Francisco (US), University of California, Irvine (US), Stanford Medicine (US), Siemens Healthcare (United States) (US), Stanford University (US)
Openalex Percentile: Top 55%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.