30-Day Outcomes of a Controlled-Bending Delivery System for TAVR in Severe Aortic Stenosis

This report presents the first-in-human experience with a 3-dimensional controlled-bending, fully retrievable delivery system for transfemoral transcatheter aortic valve replacement in severe aortic stenosis with anatomical challenge. In a prospective single-center series (September-December 2023) of 6 high-risk patients (mean age: 68.0 ± 3.9 years, 84% bicuspid valve, all with complex features such as horizontal heart or dilated ascending aorta), the device success rate was 100%, implantation was coaxial (implantation depth difference: 2.32 ± 1.53 mm), and postprocedural paravalvular leak was none to trivial. Hemodynamics improved substantially (gradient decreased from 75.5 ± 12.3 to 7.9 ± 2.1 mm Hg, effective orifice area increased from 0.61 ± 0.15 to 2.26 ± 0.34 cm<sup>2</sup>; P < 0.001). There were no deaths or strokes at 30 days postprocedure, and all patients reached NYHA functional class I or II. These early results suggest that controlled-bending delivery may enhance the precision and safety of transcatheter aortic valve replacement in complex anatomy, particularly with respect to the bicuspid valve.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2025-10-01
DOI
https://doi.org/10.1016/j.jaccas.2025.105542
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

30-Day Outcomes of a Controlled-Bending Delivery System for TAVR in Severe Aortic Stenosis

Baihua Sun, Jicheng Xi, Pinghai Zhang, Yang Chen et al.
JACC Case Reports
Cardiac Valve Diseases and Treatments
article

30-Day Outcomes of a Controlled-Bending Delivery System for TAVR in Severe Aortic Stenosis

Baihua Sun, Jicheng Xi, Pinghai Zhang, Yang Chen, Guoliang Chen, Yongjian Wu, Zhongyu Wang
article en

Abstract

This report presents the first-in-human experience with a 3-dimensional controlled-bending, fully retrievable delivery system for transfemoral transcatheter aortic valve replacement in severe aortic stenosis with anatomical challenge. In a prospective single-center series (September-December 2023) of 6 high-risk patients (mean age: 68.0 ± 3.9 years, 84% bicuspid valve, all with complex features such as horizontal heart or dilated ascending aorta), the device success rate was 100%, implantation was coaxial (implantation depth difference: 2.32 ± 1.53 mm), and postprocedural paravalvular leak was none to trivial. Hemodynamics improved substantially (gradient decreased from 75.5 ± 12.3 to 7.9 ± 2.1 mm Hg, effective orifice area increased from 0.61 ± 0.15 to 2.26 ± 0.34 cm<sup>2</sup>; P < 0.001). There were no deaths or strokes at 30 days postprocedure, and all patients reached NYHA functional class I or II. These early results suggest that controlled-bending delivery may enhance the precision and safety of transcatheter aortic valve replacement in complex anatomy, particularly with respect to the bicuspid valve.

JACC Case ReportsVol. 30(33)
Qingdao University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), ShanghaiTech University (CN), Linyi People's Hospital (CN), Fu Wai Hospital (CN), Shanxi Cardiovascular Hospital (CN)
Openalex Percentile: Top 53%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.