Development of a silica gel chromatography-based cleanup method for quantification of polystyrene nanoplastics in tissue samples via pyrolysis–GC/MS

Nanoplastics (NPs) are cause for increasing concern due to their ability to cross biological barriers, enhanced reactivity, and potentially greater toxicity than microplastics. However, their quantification in biological samples such as animal tissues remains challenging, primarily due to complex matrix interference and contamination risks. Reliable quantification of NPs in tissues is critical for understanding their bioavailability, bioaccumulation, and associated toxicological risks to animals, as well as their potential ecological risks. Here, we developed a simple yet robust method for quantifying polystyrene (PS) NPs in animal tissues using silica gel column chromatography coupled with pyrolysis–gas chromatography/mass spectrometry. Tissue samples were homogenized in dichloromethane (DCM) to extract and dissolve PS NPs in DCM and then subjected to alkaline digestion. The extract was subsequently purified using pre-heat-treated silica gel columns. The method showed high recovery rates (102.0% and 91.2% at 0.3 and 1.7 µg g⁻¹, respectively), with limits of detection and quantification of 3.0 ng and 7.8 ng, respectively. Validation with liver samples from Japanese quail orally exposed to 50 nm PS NPs revealed significantly elevated levels of PS NPs on Days 1 and 3 post-exposure (33.8 ± 1.5 and 34.1 ± 5.2 ng g⁻¹) compared to controls (13.2 ± 0.3 and 14.5 ± 2.0 ng g⁻¹) (p < 0.005). This method demonstrates effective removal of biological matrix components, enabling accurate and reproducible quantification of PS NPs in avian liver tissues. While the application to other biological samples will be explored in future studies, the method’s simplicity and minimal contamination make it a valuable tool for advancing risk assessments of NPs in biological systems. • Simple, accurate method for polystyrene (PS) nanoplastic analysis in animal tissue • Silica gel column chromatography efficiently isolate PS from biological matrices • Minimizes contamination risk during sample pretreatment • Enhances toxicity assessment and contamination monitoring in organisms

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials Letters
Published
2025-10-25
DOI
https://doi.org/10.1016/j.hazl.2025.100166
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a silica gel chromatography-based cleanup method for quantification of polystyrene nanoplastics in tissue samples via pyrolysis–GC/MS

Yoshinori Ikenaka, Yurika Tokunaga, Mayumi Ishizuka, Go Suzuki et al.
Journal of Hazardous Materials Letters
Microplastics and Plastic Pollution
article

Development of a silica gel chromatography-based cleanup method for quantification of polystyrene nanoplastics in tissue samples via pyrolysis–GC/MS

Yoshinori Ikenaka, Yurika Tokunaga, Mayumi Ishizuka, Go Suzuki, Shouta M.M. Nakayama, Kosuke Tanaka, N Shimizu
article en

Abstract

Nanoplastics (NPs) are cause for increasing concern due to their ability to cross biological barriers, enhanced reactivity, and potentially greater toxicity than microplastics. However, their quantification in biological samples such as animal tissues remains challenging, primarily due to complex matrix interference and contamination risks. Reliable quantification of NPs in tissues is critical for understanding their bioavailability, bioaccumulation, and associated toxicological risks to animals, as well as their potential ecological risks. Here, we developed a simple yet robust method for quantifying polystyrene (PS) NPs in animal tissues using silica gel column chromatography coupled with pyrolysis–gas chromatography/mass spectrometry. Tissue samples were homogenized in dichloromethane (DCM) to extract and dissolve PS NPs in DCM and then subjected to alkaline digestion. The extract was subsequently purified using pre-heat-treated silica gel columns. The method showed high recovery rates (102.0% and 91.2% at 0.3 and 1.7 µg g⁻¹, respectively), with limits of detection and quantification of 3.0 ng and 7.8 ng, respectively. Validation with liver samples from Japanese quail orally exposed to 50 nm PS NPs revealed significantly elevated levels of PS NPs on Days 1 and 3 post-exposure (33.8 ± 1.5 and 34.1 ± 5.2 ng g⁻¹) compared to controls (13.2 ± 0.3 and 14.5 ± 2.0 ng g⁻¹) (p < 0.005). This method demonstrates effective removal of biological matrix components, enabling accurate and reproducible quantification of PS NPs in avian liver tissues. While the application to other biological samples will be explored in future studies, the method’s simplicity and minimal contamination make it a valuable tool for advancing risk assessments of NPs in biological systems. • Simple, accurate method for polystyrene (PS) nanoplastic analysis in animal tissue • Silica gel column chromatography efficiently isolate PS from biological matrices • Minimizes contamination risk during sample pretreatment • Enhances toxicity assessment and contamination monitoring in organisms

Journal of Hazardous Materials LettersVol. 6
Health Sciences University of Hokkaido (JP), National Institute for Environmental Studies (JP), Hokkaido University (JP), North-West University (ZA), University of Zambia (ZM), Hokkaido University Hospital (JP)
Openalex Percentile: Top 76%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.