Conformable Endovascular Aneurysm Repair (EVAR) Stability in Hostile Neck Abdominal Aortic Aneurysms: A Single-Center Experience

Background Stent graft migration is a well-recognized complication of endovascular aneurysm repair (EVAR) that can predispose patients to type I endoleaks, renal artery compromise, and secondary interventions, particularly in cases with hostile neck anatomy, which poses a significant technical challenge for graft fixation. The GORE Excluder Conformable AAA Endoprosthesis (CLEVAR) is specifically designed to address these challenges by accommodating neck lengths as short as 10 mm, diameters down to 16 mm, and angulations up to 90°. This study aimed to evaluate the early stability and safety of the CLEVAR in patients with hostile neck anatomy by assessing its migration behavior within the first postoperative year. Methodology This retrospective, single-center study analyzed consecutive patients who underwent repair of hostile neck abdominal aortic aneurysms with the CLEVAR device between January 2019 and December 2022, focusing on early (≤1 year) postoperative stability. Eligible patients completed both three-month and one-year postoperative CT angiography. Migration was assessed by measuring the distance between the proximal stent edge and the bilateral renal arteries at both time points, with the difference representing stent movement. Descriptive statistics were calculated, normality was tested using the Shapiro-Wilk method, and comparisons were performed with nonparametric Wilcoxon signed-rank tests. Results A total of 25 patients were included. The mean stent migration across the cohort was 1.29 mm (SD 1.36 mm), with a median of 0.85 mm and a maximum migration of 6.0 mm. Both right and left renal reference points showed similar results (mean 1.17 mm and 1.40 mm, respectively), with no statistically significant difference between sides (p = 0.4261). Migration distributions were non-normally distributed and positively skewed. Analysis confirmed that stent displacement was statistically greater than zero (p < 0.00000001), indicating measurable, albeit small, positional changes during the interval. Conclusions In this study, the CLEVAR device demonstrated stable proximal fixation in challenging hostile neck anatomies over the first postoperative year. Observed migration was minimal, symmetrical, and well below thresholds considered clinically significant. These findings suggest that CLEVAR provides reliable early stability in anatomically complex aneurysm necks, potentially reducing the risk of migration-associated complications. However, the small sample size, retrospective design, and one-year follow-up limit generalizability. Longer-term studies with larger cohorts are needed to confirm the durability of fixation and explore the relationship between late migration, endoleak incidence, and the need for reintervention.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-25
DOI
https://doi.org/10.7759/cureus.95395
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conformable Endovascular Aneurysm Repair (EVAR) Stability in Hostile Neck Abdominal Aortic Aneurysms: A Single-Center Experience

Mohamed Eltayeb Abdelrahman Naiem, Ayman Zyada, Bryce Renwick, R. Hegde
Cureus
Aortic aneurysm repair treatments
article

Conformable Endovascular Aneurysm Repair (EVAR) Stability in Hostile Neck Abdominal Aortic Aneurysms: A Single-Center Experience

Mohamed Eltayeb Abdelrahman Naiem, Ayman Zyada, Bryce Renwick, R. Hegde
article en

Abstract

Background Stent graft migration is a well-recognized complication of endovascular aneurysm repair (EVAR) that can predispose patients to type I endoleaks, renal artery compromise, and secondary interventions, particularly in cases with hostile neck anatomy, which poses a significant technical challenge for graft fixation. The GORE Excluder Conformable AAA Endoprosthesis (CLEVAR) is specifically designed to address these challenges by accommodating neck lengths as short as 10 mm, diameters down to 16 mm, and angulations up to 90°. This study aimed to evaluate the early stability and safety of the CLEVAR in patients with hostile neck anatomy by assessing its migration behavior within the first postoperative year. Methodology This retrospective, single-center study analyzed consecutive patients who underwent repair of hostile neck abdominal aortic aneurysms with the CLEVAR device between January 2019 and December 2022, focusing on early (≤1 year) postoperative stability. Eligible patients completed both three-month and one-year postoperative CT angiography. Migration was assessed by measuring the distance between the proximal stent edge and the bilateral renal arteries at both time points, with the difference representing stent movement. Descriptive statistics were calculated, normality was tested using the Shapiro-Wilk method, and comparisons were performed with nonparametric Wilcoxon signed-rank tests. Results A total of 25 patients were included. The mean stent migration across the cohort was 1.29 mm (SD 1.36 mm), with a median of 0.85 mm and a maximum migration of 6.0 mm. Both right and left renal reference points showed similar results (mean 1.17 mm and 1.40 mm, respectively), with no statistically significant difference between sides (p = 0.4261). Migration distributions were non-normally distributed and positively skewed. Analysis confirmed that stent displacement was statistically greater than zero (p < 0.00000001), indicating measurable, albeit small, positional changes during the interval. Conclusions In this study, the CLEVAR device demonstrated stable proximal fixation in challenging hostile neck anatomies over the first postoperative year. Observed migration was minimal, symmetrical, and well below thresholds considered clinically significant. These findings suggest that CLEVAR provides reliable early stability in anatomically complex aneurysm necks, potentially reducing the risk of migration-associated complications. However, the small sample size, retrospective design, and one-year follow-up limit generalizability. Longer-term studies with larger cohorts are needed to confirm the durability of fixation and explore the relationship between late migration, endoleak incidence, and the need for reintervention.

CureusVol. 17(10)
Aberdeen Royal Infirmary (GB)
Openalex Percentile: Top 56%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.