Multicenter comparative analysis of FRED-X, pipeline shield, and surpass evolve in treating intracranial aneurysms

BackgroundIn recent years, newer flow diverters have been developed with surface modification and varying wire densities. Our study evaluated outcomes among three newer generation flow diverter devices, FRED-X, PED Shield and Surpass Evolve.MethodsThis was a retrospective study of patients from five participating institutions across the United States. Patients who underwent flow diversion of intracranial aneurysms using the FRED-X, PED Shield or Surpass Evolve between February 2022 and September 2024 were included. Outcomes of interest were technical success, angiographic occlusion and in-stent stenosis (ISS).ResultsAmong 447 patients with 452 aneurysms, adjunct device use was highest with Surpass Evolve (36.4%) versus PED Shield (15.7%) and FRED-X (6.4%) (<i>p</i> < .001). Good wall apposition after angioplasty/stenting was most frequent with Surpass Evolve (32.3%) versus PED Shield (13.7%) and FRED-X (4.5%) (<i>p</i> < .001). At six months, complete occlusion was achieved in 69.3% (PED Shield), 63.6% (FRED-X), and 58% (Surpass Evolve) (<i>p</i> = .254). ISS rates were comparable at six months (<i>p</i> = .826). At 12 months, complete occlusion was observed in 78.9% of PED Shield, 68.4% of FRED-X, and 64.5% of Surpass Evolve aneurysms. Most ISS cases at 12 months were mild. Kaplan-Meier analysis showed no significant difference in occlusion rates (<i>p</i> = .914).ConclusionsFlow diversion using FRED-X, PED Shield and Surpass Evolve resulted in comparable rates of angiographic occlusion and ISS. However, adjunctive devices were more commonly needed with Surpass Evolve.

Authors

Institutions

Publication Details

Journal
Interventional Neuroradiology
Published
2025-10-25
DOI
https://doi.org/10.1177/15910199251384687
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter comparative analysis of FRED-X, pipeline shield, and surpass evolve in treating intracranial aneurysms

Anna M. McNulty, Ajit S Puri, Alexandra Paúl, Elad I. Levy et al.
Interventional Neuroradiology
Intracranial Aneurysms: Treatment and Complications
article

Multicenter comparative analysis of FRED-X, pipeline shield, and surpass evolve in treating intracranial aneurysms

Anna M. McNulty, Ajit S Puri, Alexandra Paúl, Elad I. Levy, Stavropoula I. Tjoumakaris, Jaims Lim, Anna Luisa Kühn, Robert H. Rosenwasser, Yi Zhang, Matthews Lan, Pascal M. Jabbour, Arbaz A. Momin, Vinay Jaikumar, Joanna M. Roy, Michael Reid Gooch, Basel Musmar, Sravanthi Koduri, Jasmeet Singh, Spyridon Karadimas
article en

Abstract

BackgroundIn recent years, newer flow diverters have been developed with surface modification and varying wire densities. Our study evaluated outcomes among three newer generation flow diverter devices, FRED-X, PED Shield and Surpass Evolve.MethodsThis was a retrospective study of patients from five participating institutions across the United States. Patients who underwent flow diversion of intracranial aneurysms using the FRED-X, PED Shield or Surpass Evolve between February 2022 and September 2024 were included. Outcomes of interest were technical success, angiographic occlusion and in-stent stenosis (ISS).ResultsAmong 447 patients with 452 aneurysms, adjunct device use was highest with Surpass Evolve (36.4%) versus PED Shield (15.7%) and FRED-X (6.4%) (<i>p</i> < .001). Good wall apposition after angioplasty/stenting was most frequent with Surpass Evolve (32.3%) versus PED Shield (13.7%) and FRED-X (4.5%) (<i>p</i> < .001). At six months, complete occlusion was achieved in 69.3% (PED Shield), 63.6% (FRED-X), and 58% (Surpass Evolve) (<i>p</i> = .254). ISS rates were comparable at six months (<i>p</i> = .826). At 12 months, complete occlusion was observed in 78.9% of PED Shield, 68.4% of FRED-X, and 64.5% of Surpass Evolve aneurysms. Most ISS cases at 12 months were mild. Kaplan-Meier analysis showed no significant difference in occlusion rates (<i>p</i> = .914).ConclusionsFlow diversion using FRED-X, PED Shield and Surpass Evolve resulted in comparable rates of angiographic occlusion and ISS. However, adjunctive devices were more commonly needed with Surpass Evolve.

Interventional Neuroradiology
Thomas Jefferson University Hospital (US), University of Massachusetts Boston (US), Queens University (BD), Queen's Medical Center (US), Neurological Surgery (US), Hawaii Permanente Medical Group (US), University at Buffalo, State University of New York (US), Albany Medical Center Hospital (US)
Openalex Percentile: Top 56%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.