Development and evaluation of sample preparation methods for the determination of organic micropollutants in soil samples utilizing GC-APCI-QToF MS

Soil pollution poses a serious threat to terrestrial ecosystems and human health, yet studies often focus on a handful of pollutant classes per study. Wide-scope methodologies are necessary to account for the complexity and diversity of the soil matrix and the organic micropollutant mixture of both known and novel compounds it may contain. Thus, to facilitate comprehensive monitoring of the organic micropollutant burden in soil with gas chromatography coupled with high-resolution mass spectrometry (GC-HRMS), three wide-scope methods were developed and compared: modified QuEChERS (mQuEChERS), Accelerated Solvent Extraction (ASE), and Ultrasonic Assisted Extraction (UAE). Comparison of the three methods and the final choice of the modified QuEChERS were achieved via an examination of the performance characteristics, such as the number of analytes detected, recoveries, matrix effect, and precision, through a smart validation scheme that encompassed 38 analytes belonging to diverse pollutant classes. The mQuEChERS method was then fully validated for the simultaneous quantification of 75 analytes, including pesticides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), and organochlorine pesticides (OCPs). The method's limits of detection (MLOD) ranged from 0.04 to 2.77 μg kg<sup>-1</sup> d.w. Linearity was demonstrated within a concentration range of 30 to 300 μg kg<sup>-1</sup> d.w. Recoveries ranged from 70 to 120%. Method precision was deemed optimal (RSD < 11%). As proof of concept, six soil samples from Greece were analyzed, with results indicative of potential temporal variations in pollutant concentration, underscoring the necessity for extensive monitoring campaigns employing GC-HRMS.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2025-10-25
DOI
https://doi.org/10.1007/s00216-025-06187-2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and evaluation of sample preparation methods for the determination of organic micropollutants in soil samples utilizing GC-APCI-QToF MS

Georgios Gkotsis, Νikolaos S. Τhomaidis, Eleni I. Panagopoulou, Nikolaos Boinis et al.
Analytical and Bioanalytical Chemistry
Analytical chemistry methods development
article

Development and evaluation of sample preparation methods for the determination of organic micropollutants in soil samples utilizing GC-APCI-QToF MS

Georgios Gkotsis, Νikolaos S. Τhomaidis, Eleni I. Panagopoulou, Nikolaos Boinis, Nikolaos Dragazis
article en

Abstract

Soil pollution poses a serious threat to terrestrial ecosystems and human health, yet studies often focus on a handful of pollutant classes per study. Wide-scope methodologies are necessary to account for the complexity and diversity of the soil matrix and the organic micropollutant mixture of both known and novel compounds it may contain. Thus, to facilitate comprehensive monitoring of the organic micropollutant burden in soil with gas chromatography coupled with high-resolution mass spectrometry (GC-HRMS), three wide-scope methods were developed and compared: modified QuEChERS (mQuEChERS), Accelerated Solvent Extraction (ASE), and Ultrasonic Assisted Extraction (UAE). Comparison of the three methods and the final choice of the modified QuEChERS were achieved via an examination of the performance characteristics, such as the number of analytes detected, recoveries, matrix effect, and precision, through a smart validation scheme that encompassed 38 analytes belonging to diverse pollutant classes. The mQuEChERS method was then fully validated for the simultaneous quantification of 75 analytes, including pesticides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), and organochlorine pesticides (OCPs). The method's limits of detection (MLOD) ranged from 0.04 to 2.77 μg kg<sup>-1</sup> d.w. Linearity was demonstrated within a concentration range of 30 to 300 μg kg<sup>-1</sup> d.w. Recoveries ranged from 70 to 120%. Method precision was deemed optimal (RSD < 11%). As proof of concept, six soil samples from Greece were analyzed, with results indicative of potential temporal variations in pollutant concentration, underscoring the necessity for extensive monitoring campaigns employing GC-HRMS.

Analytical and Bioanalytical ChemistryVol. 417(30)
National and Kapodistrian University of Athens (GR)
Openalex Percentile: Top 65%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.