Investigation and Characterization of Clotting Artifacts in Coagulation Testing for the Development of Screening Criteria to Identify Clotted Plasma
Sample clotting substantially affects the accuracy of coagulation tests. Shortened APTT and elevated FMC and TAT serve as reliable indicators, with FDP and PIC offering time-sensitive supplementary clues. This multimodal approach could help standardize criteria for sample rejection and recollection, thereby improving test reliability and supporting clinical decisions.
Authors
- Tadashi Matsushita (ORCID: https://orcid.org/0000-0002-3646-3125)
- Atsuo Suzuki (ORCID: https://orcid.org/0000-0002-7194-3183)
- Jeong Hui Kim
- Moe Kawakami
- Mayuko Hirotsu
- Saki Shirota
Institutions
- Kobe University Hospital (JP)
- Nagoya University Hospital (JP)
Publication Details
- Journal
- International Journal of Laboratory Hematology
- Published
- 2025-10-25
- DOI
- https://doi.org/10.1111/ijlh.70019
- Primary Topic
- Clinical Laboratory Practices and Quality Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00