S298 Trapezoid RX Wire Guided Retrieval Basket Device Related Complications: Food and Drug Administration Database Analysis Involving Manufacturer and User Facility Device Experience

Introduction: According to the American Society for Gastrointestinal Endoscopy, approximately 450,000-500,000 endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed annually in the United States for diagnostic and therapeutic biliary and pancreatic interventions. Although pancreatitis and bleeding are the most common procedural complications, device-related issues account for a no 5%-10% of adverse events. Our study analyzed post-marketing surveillance data from the Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate complications associated with widely used Trapezoid RX Wire Guided Retrieval Basket during ERCP. Methods: A systematic search of Food and Drug Administration’s MAUDE database for Trapezoid reports from 2014 to 2024 was conducted. After excluding duplicates and incomplete entries, 500 adverse events were analyzed. Data were categorized by event type, device problem, and patient complications, with stratification by manufacturer-confirmed errors. Results: We reviewed 500 MAUDE database reports related to the Trapezoid device and classified adverse events into two categories: device failures and patient complications. The most common device-related issues were breakage (52.5%), material deformation (23.2%), and malfunction (15.6%). Patient-related complications were less frequent, including foreign body retention (1.6%), surgical retrieval of retained devices (1.2%), hemorrhage (0.8%), and a single case of fatal hepatic pseudoaneurysm (0.2%). Conclusion: The Trapezoid is specifically engineered to fragment and extract biliary stones during the ERCP, combining flexible navigation with rigid retrieval capabilities enhances complex biliary access, cannulation and needle-knife-free precut sphincterotomies. Analysis of MAUDE database reports highlights critical safety concerns, including device fractures, material deformations, and functional failures that demand immediate quality control measures. Additionally, the recurring issue of retained foreign bodies often necessitating repeat interventions or even exploratory surgery highlights the urgent need for enhanced procedural oversight. Moving forward, optimizing the trapezoid device's clinical utility will require dual focus: reinforcing device resilience to prevent mechanical failures and implementing standard safety guidelines to minimize complications, thereby elevating both patient safety and procedural efficacy in ERCP interventions.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001128652.36899.da
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S298 Trapezoid RX Wire Guided Retrieval Basket Device Related Complications: Food and Drug Administration Database Analysis Involving Manufacturer and User Facility Device Experience

Adlul Islam, Rahul Kumar, FNU Anjali, Aasta Kumari et al.
The American Journal of Gastroenterology
Reconstructive Surgery and Microvascular Techniques
article

S298 Trapezoid RX Wire Guided Retrieval Basket Device Related Complications: Food and Drug Administration Database Analysis Involving Manufacturer and User Facility Device Experience

Adlul Islam, Rahul Kumar, FNU Anjali, Aasta Kumari, Osama Abdur Rehman, Rahul Kumar, Aaphtaab Dheendsa, Sunny Kumar, Fnu Arti, Nikil Kumar, Fnu Aakash
article en

Abstract

Introduction: According to the American Society for Gastrointestinal Endoscopy, approximately 450,000-500,000 endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed annually in the United States for diagnostic and therapeutic biliary and pancreatic interventions. Although pancreatitis and bleeding are the most common procedural complications, device-related issues account for a no 5%-10% of adverse events. Our study analyzed post-marketing surveillance data from the Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate complications associated with widely used Trapezoid RX Wire Guided Retrieval Basket during ERCP. Methods: A systematic search of Food and Drug Administration’s MAUDE database for Trapezoid reports from 2014 to 2024 was conducted. After excluding duplicates and incomplete entries, 500 adverse events were analyzed. Data were categorized by event type, device problem, and patient complications, with stratification by manufacturer-confirmed errors. Results: We reviewed 500 MAUDE database reports related to the Trapezoid device and classified adverse events into two categories: device failures and patient complications. The most common device-related issues were breakage (52.5%), material deformation (23.2%), and malfunction (15.6%). Patient-related complications were less frequent, including foreign body retention (1.6%), surgical retrieval of retained devices (1.2%), hemorrhage (0.8%), and a single case of fatal hepatic pseudoaneurysm (0.2%). Conclusion: The Trapezoid is specifically engineered to fragment and extract biliary stones during the ERCP, combining flexible navigation with rigid retrieval capabilities enhances complex biliary access, cannulation and needle-knife-free precut sphincterotomies. Analysis of MAUDE database reports highlights critical safety concerns, including device fractures, material deformations, and functional failures that demand immediate quality control measures. Additionally, the recurring issue of retained foreign bodies often necessitating repeat interventions or even exploratory surgery highlights the urgent need for enhanced procedural oversight. Moving forward, optimizing the trapezoid device's clinical utility will require dual focus: reinforcing device resilience to prevent mechanical failures and implementing standard safety guidelines to minimize complications, thereby elevating both patient safety and procedural efficacy in ERCP interventions.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 52%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.