S426 Normative Datasets for Standard Measures of Anorectal Function With an Air Charged HRAM Catheter

Introduction: Anorectal manometry (ARM) is a core diagnostic tool for assessing anorectal function including coordination and sphincter integrity in patients with constipation and fecal incontinence. Catheter design significantly influences pressure measurements, and as such, catheter-specific normative data are critical for clinical interpretation. A novel 10-Channel Air-Charged Disposable High-Resolution Anorectal Manometry (HRAM) Catheter system (Solar catheter) was used to develop reference values for this system in healthy adults. Methods: ILLUMINATE was a prospective, multi-center, open-label study wherein each subject underwent standardized HRAM using the 10-channel, 12F air-charged disposable HRAM catheter following International Anorectal Physiology Working Group (IAPWG) and London Classification protocols. Outputs including anal resting pressure, squeeze pressure, cough pressure, and functional anal canal length were assessed. Descriptive statistics were used to generate normative datasets, stratified by gender. Results: We enrolled 81 healthy adults (21 men, 60 women; mean age = 41 ± 12 years) participated in the study. Mean anal resting pressure was 80.52 mmHg (SD ± 18.02) in men and 77.00 mmHg (SD ± 23.40) in women. No adverse events occurred. All procedures were completed without difficulty, and data collection was complete across all subjects. Conclusion: In this prospective study we describe normative anorectal pressure values and rectal sensory thresholds in healthy subjects using a novel 10-Channel Air-Charged Disposable HRAM Catheter. Some parameters, for example, maximum squeeze pressure and rectal sensory thresholds were different between genders, but most of the others were similar. These reference values could be useful when comparing data in patients with anorectal disorders and support the clinical application of air-charged disposable HRAM catheters, and it also reinforces the need for catheter-specific and gender-based data when interpreting ARM results.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001129164.07947.73
Primary Topic
Research studies in Vietnam
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S426 Normative Datasets for Standard Measures of Anorectal Function With an Air Charged HRAM Catheter

Kamran Ayub, Allan P. Weston, Delaram Asadi, Danielle Long et al.
The American Journal of Gastroenterology
Research studies in Vietnam
article

S426 Normative Datasets for Standard Measures of Anorectal Function With an Air Charged HRAM Catheter

Kamran Ayub, Allan P. Weston, Delaram Asadi, Danielle Long, Satish S. Rao, Karlo Fidel
article en

Abstract

Introduction: Anorectal manometry (ARM) is a core diagnostic tool for assessing anorectal function including coordination and sphincter integrity in patients with constipation and fecal incontinence. Catheter design significantly influences pressure measurements, and as such, catheter-specific normative data are critical for clinical interpretation. A novel 10-Channel Air-Charged Disposable High-Resolution Anorectal Manometry (HRAM) Catheter system (Solar catheter) was used to develop reference values for this system in healthy adults. Methods: ILLUMINATE was a prospective, multi-center, open-label study wherein each subject underwent standardized HRAM using the 10-channel, 12F air-charged disposable HRAM catheter following International Anorectal Physiology Working Group (IAPWG) and London Classification protocols. Outputs including anal resting pressure, squeeze pressure, cough pressure, and functional anal canal length were assessed. Descriptive statistics were used to generate normative datasets, stratified by gender. Results: We enrolled 81 healthy adults (21 men, 60 women; mean age = 41 ± 12 years) participated in the study. Mean anal resting pressure was 80.52 mmHg (SD ± 18.02) in men and 77.00 mmHg (SD ± 23.40) in women. No adverse events occurred. All procedures were completed without difficulty, and data collection was complete across all subjects. Conclusion: In this prospective study we describe normative anorectal pressure values and rectal sensory thresholds in healthy subjects using a novel 10-Channel Air-Charged Disposable HRAM Catheter. Some parameters, for example, maximum squeeze pressure and rectal sensory thresholds were different between genders, but most of the others were similar. These reference values could be useful when comparing data in patients with anorectal disorders and support the clinical application of air-charged disposable HRAM catheters, and it also reinforces the need for catheter-specific and gender-based data when interpreting ARM results.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 70%
Research studies in Vietnam
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

S426 Normative Datasets for Standard Measures of Anorectal Function With an Air Charged HRAM Catheter — Kamran Ayub, Allan P. Weston, et al. · The American Journal of Gastroenterology (2025) | TGRS Research Map | TGRS