Monitoring lung tumour volume on daily cone beam CT; is it achievable in a real-world setting?
Delineating the gross tumour volume (GTV) in non-small cell lung cancer (NSCLC) can be challenging due to anatomical complexities and imaging artefacts. This study evaluates a semi-automated workflow using commercial software for target volume (TV) delineation on cone-beam CT (CBCT) in patients undergoing radical radiotherapy. Seventy-six patients with 553 scans (n = 76 planning CT, n = 477 CBCT) were included. Auto-contours were adjusted by a senior Radiation Therapist and reviewed for accuracy. The majority (59.1 %) required only minor revisions, with median adjustment time of CBCT auto-contours of 83 (range 0-460) seconds. The findings support the feasibility of this approach, offering a pragmatic solution for adaptive radiotherapy workflows in NSCLC.
Authors
- Laure Marignol (ORCID: https://orcid.org/0000-0002-2680-6200)
- Conor K. McGarry (ORCID: https://orcid.org/0000-0001-6396-2184)
- Sarah Barrett (ORCID: https://orcid.org/0000-0003-3424-5834)
- Gerard Walls (ORCID: https://orcid.org/0000-0003-0845-9732)
- Gerard G. Hanna (ORCID: https://orcid.org/0000-0003-1003-5138)
Institutions
- Queen's University Belfast (GB)
- Belfast Health and Social Care Trust (GB)
- Trinity College Dublin (IE)
- St. Luke's Hospital (IE)
Publication Details
- Journal
- Technical Innovations & Patient Support in Radiation Oncology
- Published
- 2025-10-25
- DOI
- https://doi.org/10.1016/j.tipsro.2025.100352
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Varian Medical Systems