Strengthening of RC flat slab-column connections against punching shear using engineered cementitious composites (ECC) with PE and hybrid steel/PE fibres: An experimental and theoretical study

Engineered cementitious composite (ECC) exhibits excellent tensile properties and strain-hardening behaviour, which has proven to be a potential material for addressing the brittle failure mode occurred in reinforced concrete (RC) flat systems. This study employs a systematic experimental and theoretical approach to investigate the improvement of punching shear behaviour in slab-column connections through the incorporation of ECC. Eight connections were designed accounting for the effects of ECC zone area, steel reinforcement ratio, and fibre type and dosage in ECC, which were subjected to concentric loading to investigate the load-bearing capacity, crack patterns, deformation characteristics and failure mechanisms. Experimental results indicate that all specimens ultimately failed through punching shear, while ECC-enhanced connections exhibited significantly improved ductility compared to conventional RC counterparts. ECC increased the first crack load and load-bearing capacity of connections by 18.58–33.31 % and 34.15–37.76 %, respectively. Yielding of the reinforcing bars was observed in all specimens, with higher reinforcement ratios and fibre dosages enhancing the yield load. Increasing the polyethylene (PE) fibre dosage in ECC from 1.0 % to 2.0 % led to a rise of the load capacity, deformation resistance and yield load. ECC with hybrid steel (0.5 %) and PE (1.5 %) fibres enhanced the structural stiffness but had a negligible effect on punching shear capacity when compared to ECC containing 2 % PE fibres. Punching shear failure surfaces consistently formed outside the ECC zone, effectively expanding the base perimeter of the shear cone and increasing the critical punching shear crack angle, which was considered to determine the critical section coefficient k . Applying the modified k to GB50010–2010 and DIN 1045–1 provisions gave accurate predictions of the punching shear strength for ECC-enhanced connections featuring critical sections of the punching shear cones outside the ECC zone.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2025-10-25
DOI
https://doi.org/10.1016/j.cscm.2025.e05473
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strengthening of RC flat slab-column connections against punching shear using engineered cementitious composites (ECC) with PE and hybrid steel/PE fibres: An experimental and theoretical study

Mingzhong Zhang, Chang Wu, Xinru Wang, Yanli Su et al.
1 citations
Case Studies in Construction Materials
Structural Behavior of Reinforced Concrete
1.01
article

Strengthening of RC flat slab-column connections against punching shear using engineered cementitious composites (ECC) with PE and hybrid steel/PE fibres: An experimental and theoretical study

Mingzhong Zhang, Chang Wu, Xinru Wang, Yanli Su, Mingwen Xu, Chenhua Jin
article en
1 citations

Abstract

Engineered cementitious composite (ECC) exhibits excellent tensile properties and strain-hardening behaviour, which has proven to be a potential material for addressing the brittle failure mode occurred in reinforced concrete (RC) flat systems. This study employs a systematic experimental and theoretical approach to investigate the improvement of punching shear behaviour in slab-column connections through the incorporation of ECC. Eight connections were designed accounting for the effects of ECC zone area, steel reinforcement ratio, and fibre type and dosage in ECC, which were subjected to concentric loading to investigate the load-bearing capacity, crack patterns, deformation characteristics and failure mechanisms. Experimental results indicate that all specimens ultimately failed through punching shear, while ECC-enhanced connections exhibited significantly improved ductility compared to conventional RC counterparts. ECC increased the first crack load and load-bearing capacity of connections by 18.58–33.31 % and 34.15–37.76 %, respectively. Yielding of the reinforcing bars was observed in all specimens, with higher reinforcement ratios and fibre dosages enhancing the yield load. Increasing the polyethylene (PE) fibre dosage in ECC from 1.0 % to 2.0 % led to a rise of the load capacity, deformation resistance and yield load. ECC with hybrid steel (0.5 %) and PE (1.5 %) fibres enhanced the structural stiffness but had a negligible effect on punching shear capacity when compared to ECC containing 2 % PE fibres. Punching shear failure surfaces consistently formed outside the ECC zone, effectively expanding the base perimeter of the shear cone and increasing the critical punching shear crack angle, which was considered to determine the critical section coefficient k . Applying the modified k to GB50010–2010 and DIN 1045–1 provisions gave accurate predictions of the punching shear strength for ECC-enhanced connections featuring critical sections of the punching shear cones outside the ECC zone.

Case Studies in Construction MaterialsVol. 23
Jinling Institute of Technology (CN), University College London (GB), Southeast University (CN)
Openalex Percentile: Top 19%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.