Modeling and optimization of cranial suture anisotropic material properties using a response surface methodology

The present study aimed to develop and validate a transversely isotropic finite element (FE) model of the cranial suture that predicts suture mechanics, validated using ex-vivo data from the swine internasal suture. A 2D displacement-controlled FE model of the bone-suture-bone complex was constructed using microcomputed tomography (μCT) images, with a uniform cross-section and boundary conditions replicating experimental tensile tests. Suture geometry was modeled at three evenly spaced positions to explore how material anisotropy captures regional mechanical variation. Collagen fiber orientation was quantified from histological sections based on fiber angles relative to the suture-bone interface. Transversely isotropic material parameters were identified and optimized to match ex-vivo experimental outcomes using response surface methodology (RSM) with a five-level central composite design. Nodal forces at the displaced bone face were used from FE simulations to compare with experimental force-displacement measurements. Analysis of variance revealed that shear modulus (G<sub>xy</sub>), and Young's moduli (E<sub>y</sub>, and E<sub>x</sub>) significantly influenced force response (p < 0.05). Transitioning from isotropic to transversely isotropic material behavior led to a reduction in strain energy within the suture. Regional variation in suture interdigitation and thickness affected fiber alignment, enabling greater deformation and influencing mechanical behavior. The presented study developed a 2D FE model that incorporated transversely isotropic material properties to better predict the mechanical behavior of the region-specific internasal suture geometry. By incorporating histology-based collagen fiber orientation and optimizing transversely isotropic material properties using experimental data, the model captured region-specific mechanical responses, offering new insight into the structural role of anisotropy in cranial suture mechanics.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-10-25
DOI
https://doi.org/10.1016/j.jmbbm.2025.107245
Primary Topic
Craniofacial Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and optimization of cranial suture anisotropic material properties using a response surface methodology

Dan L. Romanyk, Michael R. Doschak, Mahzad Sadati, Karyne N. Rabey et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Craniofacial Disorders and Treatments
article

Modeling and optimization of cranial suture anisotropic material properties using a response surface methodology

Dan L. Romanyk, Michael R. Doschak, Mahzad Sadati, Karyne N. Rabey, Michael Baggaley, Lindsey Westover, Kavya Weerasinghe
article en

Abstract

The present study aimed to develop and validate a transversely isotropic finite element (FE) model of the cranial suture that predicts suture mechanics, validated using ex-vivo data from the swine internasal suture. A 2D displacement-controlled FE model of the bone-suture-bone complex was constructed using microcomputed tomography (μCT) images, with a uniform cross-section and boundary conditions replicating experimental tensile tests. Suture geometry was modeled at three evenly spaced positions to explore how material anisotropy captures regional mechanical variation. Collagen fiber orientation was quantified from histological sections based on fiber angles relative to the suture-bone interface. Transversely isotropic material parameters were identified and optimized to match ex-vivo experimental outcomes using response surface methodology (RSM) with a five-level central composite design. Nodal forces at the displaced bone face were used from FE simulations to compare with experimental force-displacement measurements. Analysis of variance revealed that shear modulus (G<sub>xy</sub>), and Young's moduli (E<sub>y</sub>, and E<sub>x</sub>) significantly influenced force response (p < 0.05). Transitioning from isotropic to transversely isotropic material behavior led to a reduction in strain energy within the suture. Regional variation in suture interdigitation and thickness affected fiber alignment, enabling greater deformation and influencing mechanical behavior. The presented study developed a 2D FE model that incorporated transversely isotropic material properties to better predict the mechanical behavior of the region-specific internasal suture geometry. By incorporating histology-based collagen fiber orientation and optimizing transversely isotropic material properties using experimental data, the model captured region-specific mechanical responses, offering new insight into the structural role of anisotropy in cranial suture mechanics.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 173
University of Alberta (CA)
Openalex Percentile: Top 67%
Craniofacial Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.