X-ray reflectivity from micrometre-scaled surfaces using nanobeams

Sample and diffractometer alignment for grazing-incidence X-ray measurements become ever more crucial once the beam and surface area of interest reach the nanometre scale. Here we show how a point of interest on a surface can be kept in the beam while measuring X-ray reflectivity, even if it is not in the centre of rotation, either because of systematic errors or additional unwanted angle-dependent sample movement. This can be achieved by a 1D trajectory scan varying the angle of incidence (θ), the detector angle (2θ) and the position of the sample along one axis in the scattering plane. As an example, we show the results of X-ray reflectivity measured from a 10 × 10 µm Au island using a 90 nm beam. Data analysis is presented which considers the angle-dependent X-ray beam footprint illuminating both the Au island and the surrounding support.

Authors

Institutions

Publication Details

Journal
Journal of Applied Crystallography
Published
2025-09-29
DOI
https://doi.org/10.1107/s1600576725008179
Primary Topic
Surface and Thin Film Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-ray reflectivity from micrometre-scaled surfaces using nanobeams

Vedran Vonk, Steffen Tober, Andreas Stierle, Breno Rabelo Coutinho Saraiva et al.
Journal of Applied Crystallography
Surface and Thin Film Phenomena
article

X-ray reflectivity from micrometre-scaled surfaces using nanobeams

Vedran Vonk, Steffen Tober, Andreas Stierle, Breno Rabelo Coutinho Saraiva, Lisa Randolph, Arti Dangwal Pandey, Steven Leake, Thomas F. Keller, Hans‐Georg Steinrück
article en

Abstract

Sample and diffractometer alignment for grazing-incidence X-ray measurements become ever more crucial once the beam and surface area of interest reach the nanometre scale. Here we show how a point of interest on a surface can be kept in the beam while measuring X-ray reflectivity, even if it is not in the centre of rotation, either because of systematic errors or additional unwanted angle-dependent sample movement. This can be achieved by a 1D trajectory scan varying the angle of incidence (θ), the detector angle (2θ) and the position of the sample along one axis in the scattering plane. As an example, we show the results of X-ray reflectivity measured from a 10 × 10 µm Au island using a 90 nm beam. Data analysis is presented which considers the angle-dependent X-ray beam footprint illuminating both the Au island and the surrounding support.

Journal of Applied CrystallographyVol. 58(6)
Universität Hamburg (DE), Forschungszentrum Jülich (DE), Deutsches Elektronen-Synchrotron DESY (DE), European Synchrotron Radiation Facility (FR), RWTH Aachen University (DE)
Deutsches Elektronen-Synchrotron
Openalex Percentile: Top 75%
Surface and Thin Film Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

X-ray reflectivity from micrometre-scaled surfaces using nanobeams — Vedran Vonk, Steffen Tober, et al. · Journal of Applied Crystallography (2025) | TGRS Research Map | TGRS