Air-source ammonia heat pump for district heating: a field modeling approach with focus on frosting-defrosting cycles

• Evaporator field optimization for district heating heat pumps. • Dedicated model for frost formation in fin-and-tube evaporators. • Experimental validation with transient tests in frosting and defrosting. • Numerous field configurations and defrosting strategies considered. • Best design options largely different when including or excluding frost formation. Frost formation on air-source evaporators in cold and humid climates significantly increases energy consumption due to airflow obstruction and thermal insulation. While this issue is well recognized, effective control strategies for multi-evaporator fields remain underexplored. This paper presents a novel evaporator model that combines experimental validation under transient frosting conditions with a new algorithm for solving frost accumulation and defrosting process across an entire evaporator field coupled to the heat pump cycle. The model is applied to simulate a large-scale ammonia heat pump serving a Danish district heating network over an annual period. Results show that neglecting frosting in design analyses can lead to strongly overestimated performance, with total costs increasing by up to 70 % once frost and defrosting cycles are considered. The study also identifies an optimal field configuration of 80 evaporators with a fin pitch of 9 mm and an airflow velocity of 3.5 m/s, and shows that defrosting 20 % of the field simultaneously is more effective than defrosting 10 %. Overall, the outcomes emphasize the critical importance of accounting for frost and defrosting cycles in thermo-economic optimization, showing that the optimal design depends on local climatic conditions and should be supported by dedicated modelling tools.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-10-25
DOI
https://doi.org/10.1016/j.applthermaleng.2025.128790
Citations
3
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
2.14
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air-source ammonia heat pump for district heating: a field modeling approach with focus on frosting-defrosting cycles

Luca Viscito, U Merlo, Francesco Pelella, S Filippini et al.
3 citations
Applied Thermal Engineering
Heat Transfer and Optimization
2.14
article

Air-source ammonia heat pump for district heating: a field modeling approach with focus on frosting-defrosting cycles

Luca Viscito, U Merlo, Francesco Pelella, S Filippini, A.W. Mauro, Adelso Flaviano Passarelli
article en
3 citations

Abstract

• Evaporator field optimization for district heating heat pumps. • Dedicated model for frost formation in fin-and-tube evaporators. • Experimental validation with transient tests in frosting and defrosting. • Numerous field configurations and defrosting strategies considered. • Best design options largely different when including or excluding frost formation. Frost formation on air-source evaporators in cold and humid climates significantly increases energy consumption due to airflow obstruction and thermal insulation. While this issue is well recognized, effective control strategies for multi-evaporator fields remain underexplored. This paper presents a novel evaporator model that combines experimental validation under transient frosting conditions with a new algorithm for solving frost accumulation and defrosting process across an entire evaporator field coupled to the heat pump cycle. The model is applied to simulate a large-scale ammonia heat pump serving a Danish district heating network over an annual period. Results show that neglecting frosting in design analyses can lead to strongly overestimated performance, with total costs increasing by up to 70 % once frost and defrosting cycles are considered. The study also identifies an optimal field configuration of 80 evaporators with a fin pitch of 9 mm and an airflow velocity of 3.5 m/s, and shows that defrosting 20 % of the field simultaneously is more effective than defrosting 10 %. Overall, the outcomes emphasize the critical importance of accounting for frost and defrosting cycles in thermo-economic optimization, showing that the optimal design depends on local climatic conditions and should be supported by dedicated modelling tools.

Applied Thermal EngineeringVol. 282
Libera Università Internazionale degli Studi Sociali Guido Carli (IT), University of Naples Federico II (IT)
Openalex Percentile: Top 12%
Heat Transfer and Optimization
2.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Air-source ammonia heat pump for district heating: a field modeling approach with focus on frosting-defrosting cycles — Luca Viscito, U Merlo, et al. · Applied Thermal Engineering (2025) | TGRS Research Map | TGRS