Flow patterns through side holes of venous cannula in mock circulation loop

Cannulae with multi-staged side holes (SHs) for venous drainage are widely used for performing extracorporeal circulation. Various types of catheters are used worldwide; however, data on the flow performance of each catheter are lacking or inaccurate. Clinical applications are often intuitive. In this study, we aimed to develop a mock circulation loop for cannula performance evaluation. We found no differences in the rate of change in the flow rate through each SH as the pump flow increased when the pump flow rate was 250 to 750 mL/min. When the pump flow rate was ≥ 750 mL/min, there was an increase in the rate of change in the flow rate through each side hole toward the proximal side hole and the percentage inflow of the proximal side hole and decrease in percentage inflow toward the distal side hole, as the pump flow increased. Thus, we believe that the desired venous drainage can be applied to patients, and the fluid dynamical structures of catheters in the human body can be estimated according to the type of catheter or its location in the human body. The findings of this study will aid in designing new catheters.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-10-24
DOI
https://doi.org/10.1097/md.0000000000045016
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow patterns through side holes of venous cannula in mock circulation loop

Seong Ho Moon, Joung Hun Byun, Sang‐Kwon Lee, Dong Hoon Kang et al.
Medicine
Mechanical Circulatory Support Devices
article

Flow patterns through side holes of venous cannula in mock circulation loop

Seong Ho Moon, Joung Hun Byun, Sang‐Kwon Lee, Dong Hoon Kang, Ho Jeong, Jong Woo Kim
article en

Abstract

Cannulae with multi-staged side holes (SHs) for venous drainage are widely used for performing extracorporeal circulation. Various types of catheters are used worldwide; however, data on the flow performance of each catheter are lacking or inaccurate. Clinical applications are often intuitive. In this study, we aimed to develop a mock circulation loop for cannula performance evaluation. We found no differences in the rate of change in the flow rate through each SH as the pump flow increased when the pump flow rate was 250 to 750 mL/min. When the pump flow rate was ≥ 750 mL/min, there was an increase in the rate of change in the flow rate through each side hole toward the proximal side hole and the percentage inflow of the proximal side hole and decrease in percentage inflow toward the distal side hole, as the pump flow increased. Thus, we believe that the desired venous drainage can be applied to patients, and the fluid dynamical structures of catheters in the human body can be estimated according to the type of catheter or its location in the human body. The findings of this study will aid in designing new catheters.

MedicineVol. 104(43)
Changwon National University (KR), Zero to Three (US), S.P.E.C.I.E.S. (US)
Openalex Percentile: Top 70%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.